Why  Hubbell
Model A Features
Model A Dimensions
A Recovery Ratings
Model B Features
Model B Dimensions
B Recovery Ratings
Model # Selection
Operating Manual
Model A Recovery Ratings
To Model AB Intro

Model A6

Model A15

Base
Model
Number

KW
Rating

Recovery Rate in GPH For
oF Temperature Rise Listed Below

20o

40o

60o

70o

80o

100o

140o

A64

4

82

41

27

23

21

16

7

A65

5

103

51

34

29

26

21

8

A66

6

123

62

41

35

31

25

10

A67

7

144

72

48

41

36

29

11

A68

8

164

82

55

47

41

33

13

A69

9

185

92

62

53

46

37

15

A610

10

205

103

68

59

51

41

16

A612

12

246

123

82

70

62

49

20

A613

13

267

133

89

76

67

53

21

A615

15

308

154

103

88

77

62

25

A618

18

369

185

123

105

92

74

30

Base
Model
Number

KW
Rating

Recovery Rate in GPH For
oF Temperature Rise Listed Below

20o

40o

60o

70o

80o

100o

140o

A1512

12

246

123

82

70

62

49

20

A1515

15

308

154

103

88

77

62

25

A1520

20

410

205

137

117

103

82

33

A1524

24

492

246

164

141

123

98

39

A1530

30

615

308

205

176

154

123

49

A1535

35

718

359

239

205

179

144

57

A1540

40

820

410

273

234

205

164

66

A1545

45

923

461

308

264

231

185

74

A1554

54

1107

554

369

316

277

221

89

A1558

58

1189

595

396

340

297

238

95

 

 

Hot Water Heaters Home | Hot Water Heaters Selection Guide | Rep Listing | Contact Hubbell Heaters

Low Capacity Electric Water Heaters | High Capacity Electric Water Heaters | Special Purpose Water Heaters | Steam Fired Water Heaters | Indirect / Direct Fired Water Heaters | Heating Elements & Coils

Hubbell HeaterswThe Electric Heater CompanywP.O.Box 288 wStratford, CT 06615-0288
Phone: (203) 378-2659
wFax:(203) 378-3593wEmail: info@hubbellheaters.com