Step 1
Solve for the unknown using the formulas stated below.Variables To Solve For:1. KW Requirement: GPM x oFDT x 0.1465 = KW
2. Temperature Rise: KW x 6.824 ÷ GPM = oFDT
3. Flow Rate: KW x 6.824 ÷ oFDT = GPM
Step 2
Choose the CR model with the KW rating which meets the peak demand (GPM) of your system.
Step 3
Choose the voltage and phase power supply available. Note the total amperage draw of the unit and verify availability.
Electrical
KW X 1000_______________ ÷ 1.73 = Amps 3 F Volts
Note:Each branch circuit in the CR Model is rated at a maximum of 48 Amps and each circuit is typically operated as an independent temperature step.
KW X 1000_______________ = Amps 1 F Volts
Example:
Model CR225MT4 is 225 KW at 480 V 3 F.
225
271 ÷ 48 Amps max circuit rating= 5.6Round up to 6 for the number of heating load temperature steps