    General
  • Packaged unit UL listed and labeled
  • ASME Code Section IV stamped tank registered with the National Board of Boiler and Pressure Vessel Inspectors and stamped for 160psi working pressure
  • Certified by the California Energy Commission
  • Exceeds ASHRAE 90.1b-1992 standards for thermal efficiency and standby heat loss
  • 83% non-condensing efficiency
  • 3" fiberglass insulation with 22 gauge galvanized steel protective jacket
  • UL and ASME approved high quality polymer lining with 100% guaranteed coverage over a base layer of flame spray copper
  • Fire Tube Turbulators for maximum heat transfer efficiencies
  • 3" Hand Hole Clean out
  • Built-in magnesium anode(s) with a tell tale replacement indication system
  • Dielectric inlet and outlet water connections
  • Flame observation port
  • Drain with 2" ball valve
  • Heavy duty steel platform
  • Seismic IV compliant
  • Lifting Lugs


  • #1 and #2 Fuel Oil
  • Cadium sulfide cell and relay control
  • 10,000 Volt constant duty ignition transformer
  • Solenoid oil valve(s)
  • Burner mounted 3500 RPM fuel pump
  • 3500 RPM blower motor



    Natural Gas & LP Gas
  • Dual operating and safety gas valves
  • Flame rod with 4 second safety shutdown
  • Ultraviolet scanning (standard on LP Gas burners only)
  • Pre and Post Purge combustion control (standard on all burners over 2500MBH)
  • High and Low gas pressure switches (standard on all burners over 2500MBH)
  • 30 second pre-purge
  • Safety air flow switch
  • Direct spark ignition with 6000 Volt transformer
  • 3450 RPM blower motor


  • Controls
  • Packaged fuel burner UL listed and labeled
  • 120 Volt 1 Phase 60 Hz control circuit operation
  • Hi-limit thermostat with manual reset
  • Upper and lower operating thermostats (upper thermostat acts as an automatic resetting hi-limit)
  • Low water cut out with manual reset, test button, and indicating light
  • ASME rated combination temperature and pressure relief valve set at 150psi, 210oF
 