Specs
Heating Coils
Optional Equipment
Dimensions
Ordering Info
Submittal Specs
Operating Manual
Back To SLN Intro
Model SLN Optional Equipment
  1. Double wall heating coil with a leak detection port
  2. 11/2" Male NPT inlet and outlet water connections
  3. Electric heating element for back-up heating, please specify wattage and voltage.
  4. Integrally welded seismic attachment points

Back-up Electric Heating
Element Selection Chart

Voltage

Phase

KW Ratings Available

120

1

1.5, 2

208, 240, 277, 480

1

 3, 4, 4.5, 5, 6

208 thru 480

3

6, 8, 10, 12, 15, 20

Notes:

  1. If an electric back-up heater is required, it is typically installed in the upper element bank position. On 120 gallon models only, an element can also be added in the lower element bank position. If this dual heating element arrangement is desired, they will be wired for non-simultaneous operation to allow only one electric heater to come on line at one time. Electric back up heating is specified in the last part of the model number. (1=upper position only, 2=upper and lower position).
  2. A typical selection for a solar heater with electric back up is 4.5 KW at 240V 1Phase.
  3. 1 KW will heat 4.1 GPH 40-140oF (100oF Rise).
 

Hot Water Heaters Home | Hot Water Heaters Selection Guide | Rep Listing | Contact Hubbell Heaters

Low Capacity Electric Water Heaters | High Capacity Electric Water Heaters | Special Purpose Water Heaters | Steam Fired Water Heaters | Indirect / Direct Fired Water Heaters | Heating Elements & Coils

Hubbell HeaterswThe Electric Heater CompanywP.O.Box 288 wStratford, CT 06615-0288
Phone: (203) 378-2659
wFax:(203) 378-3593wEmail: info@hubbellheaters.com