Electric Low Capacity

Light Duty Commercial

Electric cement lined water heater Model E
  • Light Duty
  • 6 - 120 Gallon Capacity
  • Up to 12KW - 1 Phase or 3 Phase

Ceiling Hung Horizontal

Electric horizontal ceiling hung water heater Model HE/HSE
  • Horizontal, Ceiling Hung
  • 20 or 30 Gallon Capacity
  • Up to 20 KW - 1 or 3 Phase

Heat Pump
Hybrid

Hybrid electric heat pump water heater Model PBX
  • Heat Pump Water Heater
  • 40 - 120 Gallon Capacity
  • 1 or 3 Phase

Point-Of-Use Storage

Point-of-use electric water heater Model CE110
  • Point-of-Use
  • 1 Gallon Capacity
  • 1000 or 450 Watts - 1 Phase

Point-Of-Use Tankless

Electric tankless point-of-use water heater Model R
  • Whole House / Point-of-Use
  • Availabe 3 thru 27 KW - 1 Phase

Electric
Booster

Electric booster water heater Model J
  • Booster Heater
  • Provides 180°F water
  • Up to 88 KW - 1 or 3 Phase

Tankless Electric Booster

Electric tankless booster heater Model JTX
  • Tankless Booster Heater
  • Provides 180°F water
  • 11 to 54 KW - 1 or 3 Phase

Heavy Duty Commercial

Commercial heavy duty electric storage water heater Model SE
  • Heavy Duty
  • 6-120 Gallon Capacity
  • Up to 58 KW - 3 Phase

Tankless Commercial

Electric tankless water heater Model TX
  • Tankless Commercial
  • Highly efficient tankless
  • Up to 54 KW - 1 or 3 Phase

Large ASME
Heater

Large capacity electric storage tank water heater Model SH
  • Large Capacity
  • 80-5000 Gallon Capacity
  • All KW ratings - 1 or 3 Phase
     

Commercial Gas Tankless

Gas tankless water heater Model GX
  • High Efficiency Condensing Burner
  • Integrated Pump
  • 200,000 and 250,000 BTUs

Integrated Tank with Tankless

Condensing gas storage tank water heater Model GXT
  • High Efficiency Condensing Burner
  • Hydrastone Cement
  • 200,000 to 250,000 BTUs

DI / RO Gas
Tankless

DI/RO gas fired tankless water heater Model DGX
  • DI/RO Water Heater
  • High Efficiency Condensing Burner
  • 199,950 and 250,000 BTU

Gas Tankless Booster

Condensing gas tankless booster water heater Model JBX
  • Gas Tankless Booster
  • For Commercial Kitchens
  • 250,000 BTU

Gas Storage
Heater

Condensing gas storage tank water heater Model GXT
  • Non Condensing Burner
  • Hydrastone Cement
  • 200,000 to 250,000 BTUs
   

Large ASME
Steam Heater

Steam fired water heater large capacity Model ST
  • Storage Type
  • 80-5000 Gallon Capacity
  • ASME Stamped

Packaged Semi-Instantaneous

Semi-Instantaneous Steam Fired Water Heater Model STX
  • Semi-Instantaneous
  • Space saving design
  • Provides 10,500 GPH

Point-Of-Use
Steam

Storage tank steam fired water heater Model PS
  • Light Duty
  • 80-120 Gallon Capacity
  • For low demand/recovery

High Capacity Instantaneous

Instantaneous steam fired water heater Model F
  • Instantaneous
  • 7 Sq. Ft. of floorspace
  • Up to 120 GPM
     

Semi-Instantaneous Indirect

Indirect fired semi-instantaneous water heater Hubbell Model BWX
  • Semi-Instantaneous
  • Vertical or Horizontal
  • ASME Stamped

Large ASME
Indirect

Indirect fired storage tank water heater Hubbell Model BW
  • Storage Type
  • Vertical or Horizontal
  • 80-5000 Gallon Capacity

Small Capacity Indirect

Indirect fired storage tank water heater model T Transflow
  • Indirect Fired
  • 30-120 Gallon Capacity
  • Utilizes boiler water

Solar

Solar water heater Model SLN
  • Solar Heater
  • Vertical Storage Type
  • 30-120 Gallon Capacity
       

Storage
Tanks

ASME and None ASME storage vessels Hubbell Model StorageTank
  • ASME & Non ASME designs
  • Hydrastone Cement
  • Vertical or Horizontal

Buffer
Tanks

ASME and None ASME storage vessels Hubbell Model BufferTank
  • Carbon Steel Construction
  • Long Warranty
  • ASME Section VIII, Division 1
   
       

Circulation (Instantaneous)

Electric circulation heater Hubbell Model CR
  • Circulation (Instantaneous)
  • Heavy Duty Construction
  • 25-1600 KW - 1 or 3 Phase

Explosion
Resistant

Electric hazardous location water heater Model ER
  • Hazardous Location
  • 10-120 Gallon Capacity
  • Up to 58 KW - 1 or 3 Phase

Industrial Process Heater

Electric process industrial water heater Model V
  • Process Systems & Industrial
  • ASME Stamped
  • Up to 88 KW - 1 or 3 Phase

Emergency Shower Tankless

Electric tankless safety shower water heater Model ETX
  • Tankless Emergency Tepid Water
  • NEMA 4 Standard
  • Up to 88 KW - 1 or 3 Phase

RO / DI Heater Compact

DI/RO electric hot water heater Model HD
  • RO/DI Water Heater
  • Point-of-Use Heater
  • Up to 88 KW - 1 or 3 Phase

RO / DI Heater Storage

DI/RO electric hot water heater Model D
  • RO/DI Water Heater
  • 1-120 Gallon Capacity
  • Up to 88 KW - 1 or 3 Phase

Tepid Water for Emergency Fixtures

Electric safety shower water heater Model EMV
  • Emergency Tepid Water
  • Fully packaged system
  • Integrated mixing valve

Fully Integrated Package

Model Packaged Skid
  • Customized to your specifications
  • Full featured system ready for your application

Light Duty
Electric

Electric water heater for shipboard marine use single phase power Model ME
  • Light Duty
  • 6-120 Gallon Capacity
  • Up to 6 KW - 1 Phase

Large ASME
Electric

Electric water heater for shipboard marine use large capacity Model MSH
  • Large Capacity
  • 80-5000 Gallon Capacity
  • All KW ratings - 1 or 3 Phase

Heavy Duty
Electric

Electric water heater for shipboard marine use three phase power Model MSE
  • Vertical
  • 6-120 Gallon Capacity
  • 1 or 3 Phase - Up to 58 KW

Tankless
Electric

Electric tankless water heater for shipboard marine use model MTX
  • Tankless Marine Heater
  • Provides 180°F water
  • 11 to 54 KW - 1 or 3 Phase

Naval

Naval shipboard marine electric water heater Hubbell Model 177
  • MIL Spec Navy Heaters
  • Comforms to MIL-H-965
  • Shock and EMI protection

Fully Integrated Package

Turn-key hot water system
  • Customized to your specifications
  • Full featured system ready for your application
   

Immersion Heating
Elements

Electric immersion tubular style heaters
  • Immersion Electric Heaters
  • Flanged or Screw Plugs Types
  • All KW ratings - 1 or 3 Phase

Heat Transfer
Coils

Heat exchanger and heating coil water heaters
  • Immersion Heat Transfer Coils
  • U tube type
  • Range of Materials
   
       
Electric High Capacity
Gas Fired
Steam Fired
Indirect
Storage
Special Purpose
Marine
Elements & Exchangers
Resource Center
ASME and Non ASME Storage Vessels
Still have questions? Complete this form
*Name:
*Email:
*State /
Province:
*Comment:

Model Buffer Tanks

Capacities up to 5000 Gallons

The primary function of a buffer tank is to prevent short cycling of a boiler or chiller. Buffer tanks store energy produced in a boiler or chiller and release this energy as required into the system. Typical systems operate well below design loads and the use of a buffer tank introduces this stored energy in lieu of cycling the boiler or chiller, this reduction in cycling increases equipment longevity.

Hubbell offers traditional two and four port design configurations with a range of connection sizes as referenced in our submittal data sheets. To meet the wide scope of job site specific connection sizes, the Hubbell buffer tank can also be configured with owner specific requirements.


cULUS Listed
  • Specifications

    • Designed and constructed per ASME Section VIII, Dvision 1
    • Construction: Carbon Steel with Exterior red oxide primer finish
    • Maximum Design Pressure and Temperature: 160 psi @ 375°F
    • Registered with the National Board of Pressure Vessel Manufacturers
    • Warranty 5 Years
  • Optional Features

    • 304 SS or 316L SS construction
    • Higher design pressures and temperatures
    • Alternate Connection sizes available
    • Insulation and Jacketing

Outline Dimensions

Buffer Tank Dimensional Data

2 Port Buffer Tank


INLET OUTLET
2" FNPT 2" FNPT
3" FNPT 3" FNPT
4"-150# FL'G 4"-150# FL'G
5"-150# FL'G 5"-150# FL'G
6"-150# FL'G 6"-150# FL'G


VOLUME A B C D E WEIGHT (LBS.)
DRY WET
120 GAL. 24" 58 1/2" 13" 48 1/2" 20" 398 1398
210 GAL. 30" 73 1/2" 15" 61 1/2" 24" 563 2312
300 GAL. 36" 70 1/2" 18 1/4" 55 1/2" 30" 715 3214
Note: Additional sizes available up to 5,000 gallons
Horizontal configuration available, please contact us direct.
Buffer Tank Dimensional Data 2

2 Port Buffer Tank


INLET OUTLET
2" FNPT 2" FNPT
3" FNPT 3" FNPT
4"-150# FL'G 4"-150# FL'G
*5"-150# FL'G *5"-150# FL'G
*6"-150# FL'G *6"-150# FL'G


VOLUME A B C D E WEIGHT (LBS.)
DRY WET
120 GAL. 24" 58 1/2" 13" 48 1/2" 20" 398 1398
210 GAL. 30" 73 1/2" 15" 61 1/2" 24" 563 2312
300 GAL. 36" 70 1/2" 18 1/4" 55 1/2" 30" 715 3214
Note: Additional sizes available up to 5,000 gallons
Horizontal configuration available, please contact us direct.
*Secondary inlet/outlet dimensions need to be specified.

Model StorageTank Specific Questions

Can a timer be installed on my Hubbell water heater?

Water heater timers are devices that provide automatic control of electric water heaters. They can be programmed to turn a water heater off or on at times typically set by your local utility. Your local electric utility may have in place an “Off-Peak” or Time-of-Use (TOU) rates which offer a customer the incentive to consume power during certain periods of the day. The Hubbell Model E is available with various timer control options, ranging from programmable 7 day timers to utility specific devices that control the water heater.

Why is Hydrastone Cement a better choice over glass lining?

Cement lining provides guaranteed 100% coverage with a minimum thickness of 0.5” over all internal tank surfaces. In comparison, glass lining is approximately 0.005” thick and includes imperfections, pinholes and variation in coverage thickness resulting in portions of unprotected steel tank exposed to corrosion. In an attempt to compensate, glass lined tanks include a sacrificial anode in an effort to slow down the corrosion of the tank. Cement lined tanks on the other hand do not require an anode due to the integrity of the lining. As such, a cement lined tank will far outlast a glass lined tank. For a more complete explanation of the benefits of the Hubbell cement lining please click on the following link Cement Lining

What is a sacrificial anode and does a cement lined tank need one?

All water heaters constructed using a steel tank requires a lining to protect the internal steel surfaces from corrosion. Certain linings (i.e. glass and epoxy), due to their nature, have unavoidable holes and imperfections resulting in exposure of the steel tank. As a result of this deficiency, the manufacturer will install an anode rod(s) in an attempt to delay corrosion of the steel tank. An anode rod is typically made of aluminum, magnesium or zinc, is a maintenance item that requires periodic inspection and replacement, and is often times the cause of a “rotten egg” odor to your hot water. Often referred to as a sacrificial anode rod because, over time, it slowly dissolves, sacrificing itself as it is attacked by aggressive substances in the water which would otherwise attack the steel tank through the pinholes and imperfections of the glass or epoxy lining. A cement lined steel tank on the other hand does not require an anode because of the thickness and guaranteed 100% coverage of the cement lining over all internal surfaces of the steel tank. This eliminates the need for an anode rod in a cement lined water heater, resulting in a significantly longer life compared to a glass or epoxy lined water heater. For a further discussion please click on the following link Cement Lining

What does 3 phase Open Delta wiring mean to me?

Without getting into a lengthy discourse on electricity, the simple answer is that any water heater internally wired in a 3 phase open delta configuration is unbalanced, meaning that the amperage drawn by one of the three legs is high and unequal to the other two legs. This unbalanced water heater can have a detrimental effect on a buildings power system and therefore needs to be carefully understood before you install a water heater configured for 3 phase open delta. It should be noted that the branch circuit protection (i.e. circuit breaker) servicing a 3 phase open delta water heater needs to be sized for the high amperage leg. The Hubbell model E is available up to a maximum of 12kw in 3 phase open delta wiring. Alternatively, the Hubbell model SE is a balanced 3 phase water heater, meaning that all three legs draw equal amperage. The Model SE is available up to 58kw click here details Model SE

Why is there an upper and a lower heating element in my tank?

Hubbell Model E water heaters with 30 gallon storage or more have both upper and lower heating elements in the tank, and models 20 gallon storage and less have one heating element in the tank. The purpose of having two heating elements in a tank is to improve the recovery rating in a water heater of significant storage capacity. Sometimes referred to as a “Quick Recovery” water heater, this configuration allows the upper element to heat a much smaller volume of water (about 25% of the tank's capacity) before the lower element takes over. This provides a small amount of usable hot water quickly while you wait for the bulk of the water to heat. It is worth noting that in the standard dual element design, the upper and lower heating elements are interlocked so that only one can heat at any time, with priority to the upper element. Once the thermostat controlling the upper element is satisfied (i.e. at set point temperature) the lower element is allowed to heat. As an option, you may order your Hubbell water heater with the optional “simultaneous operation” feature which allows each element to operate independently, potentially allowing both to be on at the same time in order to increase the recovery rate of the heater.

General Questions

Where can I purchase a Hubbell water heater?

There are numerous ways to purchase a Hubbell water heater depending upon the model you desire and your geographic location. The easiest way is to contact Hubbell directly at 800-647-3165 and ask for the sales department where you will be directed to either our local representative or our order entry department for quick and easy ordering.

Where can I purchase replacement parts?

Parts are available for your Hubbell water heater direct from the factory. Please call 800-647-3165 and ask for our parts department. Please have your model and serial number handy.

I don't see the size or feature I need, what do I do?

Hubbell has more than 35 product families available in over 4,000,000 configurations. There are numerous features, configurations and ratings we provide but for practical reasons are are not listed in the sales brochure. If you have a specific requirement and you do not see it in the brochure, please contact a Hubbell Sales Engineer...chances are we have what you need.

What should I know about Legionella disease?

Legionella is the bacteria responsible for Legionnaire’s Disease, an acute bacterial infection of the lower respiratory tract. This bacterium was first identified in 1977 by the Centers for Disease Control as the cause of an outbreak of pneumonia that caused 34 deaths at a 1976 American Legion Convention in Philadelphia. Pontiac Fever is a less severe, non-pneumonia, flu-like disease that is associated with and likely caused by Legionella bacteria. Legionella is a fairly common water bacterium and has been found to exist widely in many surface water sources including lakes, rivers, streams and ponds. It can also be found in ground water sources and some soils. At the levels found in these naturally occurring sources it typically does not pose a threat to public health. When the bacterium enters a domestic water system it can find an ideal host environment of warm water temperatures (105-115°F), stagnant water areas (isolated storage tanks and dead-end piping legs) and ample food sources (sediment, scale, deposits and biofilm). Under these conditions Legionella can rapidly colonize, forming higher concentrations that can pose the public health threat of Legionnaire’s Disease. There are many methods of controlling colonization of Legionella bacteria. However, a widely accepted and preferred method is to maintain the hot water system storage temperature continually at or above 140°F. Unfortunately, the elevated temperature necessary to minimize the growth of and kill Legionella bacteria has the potential to cause serious thermal shock and scalding injuries. As such, many plumbing engineers will specify that the water heater be set to maintain water temperatures at 140°F or higher to reduce the risk of Legionella, but then specify the appropriate mixing valve to ensure safe delivery of hot water to the fixtures. For a more thorough discussion of Legionella please go to here and the following link to the US Department of Labor OSHA information regarding Legionnaires’ Disease OSHA here

My question is not found in these FAQ’s, where do I look next?

Check out the Hubbell Product Center at Here for a complete listing of all technical documentation available by model. Get easy access to Installation, Operation & Maintenance manuals, Sales Brochures, Service Bulletins, Wiring Schematics, Parts Breakdowns and various other technical documents related to the full line of Hubbell water heaters. Or, if you prefer, please call us at 800-647-3165 and ask to speak to a Sales Engineer.

Downloads

Many of our products literature is available online for download. To open these files, a PDF viewer is required. If you do not have one, Adobe provides Acrobat Reader free of charge for viewing only. Use this link to download Acrobat Reader. You may also choose to download the file to your PC for future reference or printing. On most operating systems, simply right-click on the links below, choose "Save target as..." or "Save link as...", choose a location and it will save the document to your computer for future reference.

Model StorageTank Specific Questions

My question is not found in these FAQ’s, where do I look next?

Check out the Hubbell Product Center at Here for a complete listing of all technical documentation available by model. Get easy access to Installation, Operation & Maintenance manuals, Sales Brochures, Service Bulletins, Wiring Schematics, Parts Breakdowns and various other technical documents related to the full line of Hubbell water heaters. Or, if you prefer, please call us at 800-647-3165 and ask to speak to a Sales Engineer.

Where can I purchase replacement parts?

Parts are available for your Hubbell water heater direct from the factory. Please call 800-647-3165 and ask for our parts department. Please have your model and serial number handy.


For Further Assistance Please Contact a Hubbell Tech Support Rep.

Sam Wellington
samw@hubbellheaters.com
203-378-2659 x136
D.J. Dineson
djdineson@hubbellheaters.com
203-378-2659 x125
E120-6-6SLT4,
Hubbell Heaters
45 Seymour Street
P.O. Box 288
Stratford, CT 06615-0288
Tel: 203-378-2659
Fax: 203-378-3593
Product Center
Hubbell Binder

View our current digital materials available in our resource center.

To Product Center  Bullet Point