Electric Low Capacity

Light Duty Commercial

Electric cement lined water heater Model E
  • Light Duty
  • 6 - 120 Gallon Capacity
  • Up to 12KW - 1 Phase or 3 Phase

Ceiling Hung Horizontal

Electric horizontal ceiling hung water heater Model HE/HSE
  • Horizontal, Ceiling Hung
  • 20 or 30 Gallon Capacity
  • Up to 20 KW - 1 or 3 Phase

Heat Pump
Hybrid

Hybrid electric heat pump water heater Model PBX
  • Heat Pump Water Heater
  • 40 - 120 Gallon Capacity
  • 1 or 3 Phase

Point-Of-Use Storage

Point-of-use electric water heater Model CE110
  • Point-of-Use
  • 1 Gallon Capacity
  • 1000 or 450 Watts - 1 Phase

Point-Of-Use Tankless

Electric tankless point-of-use water heater Model R
  • Whole House / Point-of-Use
  • Availabe 3 thru 27 KW - 1 Phase

Electric
Booster

Electric booster water heater Model J
  • Booster Heater
  • Provides 180°F water
  • Up to 88 KW - 1 or 3 Phase

Tankless Electric Booster

Electric tankless booster heater Model JTX
  • Tankless Booster Heater
  • Provides 180°F water
  • 11 to 54 KW - 1 or 3 Phase

Heavy Duty Commercial

Commercial heavy duty electric storage water heater Model SE
  • Heavy Duty
  • 6-120 Gallon Capacity
  • Up to 58 KW - 3 Phase

Tankless Commercial

Electric tankless water heater Model TX
  • Tankless Commercial
  • Highly efficient tankless
  • Up to 54 KW - 1 or 3 Phase

Large ASME
Heater

Large capacity electric storage tank water heater Model SH
  • Large Capacity
  • 80-5000 Gallon Capacity
  • All KW ratings - 1 or 3 Phase
     

Commercial Gas Tankless

Gas tankless water heater Model GX
  • High Efficiency Condensing Burner
  • Integrated Pump
  • 200,000 and 250,000 BTUs

Integrated Tank with Tankless

Condensing gas storage tank water heater Model GXT
  • High Efficiency Condensing Burner
  • Hydrastone Cement
  • 200,000 to 250,000 BTUs

DI / RO Gas
Tankless

DI/RO gas fired tankless water heater Model DGX
  • DI/RO Water Heater
  • High Efficiency Condensing Burner
  • 199,950 and 250,000 BTU

Gas Tankless Booster

Condensing gas tankless booster water heater Model JBX
  • Gas Tankless Booster
  • For Commercial Kitchens
  • 150,000 / 200,000 / 250,000 BTU

Gas Storage
Heater

Condensing gas storage tank water heater Model GXT
  • Non Condensing Burner
  • Hydrastone Cement
  • 200,000 to 250,000 BTUs
   

Large ASME
Steam Heater

Steam fired water heater large capacity Model ST
  • Storage Type
  • 80-5000 Gallon Capacity
  • ASME Stamped

Packaged Semi-Instantaneous

Semi-Instantaneous Steam Fired Water Heater Model STX
  • Semi-Instantaneous
  • Space saving design
  • Provides 10,500 GPH

Point-Of-Use
Steam

Storage tank steam fired water heater Model PS
  • Light Duty
  • 80-120 Gallon Capacity
  • For low demand/recovery

High Capacity Instantaneous

Instantaneous steam fired water heater Model F
  • Instantaneous
  • 7 Sq. Ft. of floorspace
  • Up to 120 GPM
     

Semi-Instantaneous Indirect

Indirect fired semi-instantaneous water heater Hubbell Model BWX
  • Semi-Instantaneous
  • Vertical or Horizontal
  • ASME Stamped

Large ASME
Indirect

Indirect fired storage tank water heater Hubbell Model BW
  • Storage Type
  • Vertical or Horizontal
  • 80-5000 Gallon Capacity

Small Capacity Indirect

Indirect fired storage tank water heater model T Transflow
  • Indirect Fired
  • 30-120 Gallon Capacity
  • Utilizes boiler water

Solar

Solar water heater Model SLN
  • Solar Heater
  • Vertical Storage Type
  • 30-120 Gallon Capacity
       

Storage
Tanks

ASME and None ASME storage vessels Hubbell Model StorageTank
  • ASME & Non ASME designs
  • Hydrastone Cement
  • Vertical or Horizontal
     
       

Circulation (Instantaneous)

Electric circulation heater Hubbell Model CR
  • Circulation (Instantaneous)
  • Heavy Duty Construction
  • 25-1600 KW - 1 or 3 Phase

Explosion
Resistant

Electric hazardous location water heater Model ER
  • Hazardous Location
  • 10-120 Gallon Capacity
  • Up to 58 KW - 1 or 3 Phase

Industrial Process Heater

Electric process industrial water heater Model V
  • Process Systems & Industrial
  • ASME Stamped
  • Up to 88 KW - 1 or 3 Phase

Emergency Shower Tankless

Electric tankless safety shower water heater Model ETX
  • Tankless Emergency Tepid Water
  • NEMA 4 Standard
  • Up to 88 KW - 1 or 3 Phase

RO / DI Heater Compact

DI/RO electric hot water heater Model HD
  • RO/DI Water Heater
  • Point-of-Use Heater
  • Up to 88 KW - 1 or 3 Phase

RO / DI Heater Storage

DI/RO electric hot water heater Model D
  • RO/DI Water Heater
  • 1-120 Gallon Capacity
  • Up to 88 KW - 1 or 3 Phase

Tepid Water for Emergency Fixtures

Electric safety shower water heater Model EMV
  • Emergency Tepid Water
  • Fully packaged system
  • Integrated mixing valve

Fully Integrated Package

Model Packaged Skid
  • Customized to your specifications
  • Full featured system ready for your application

Light Duty
Electric

Electric water heater for shipboard marine use single phase power Model ME
  • Light Duty
  • 6-120 Gallon Capacity
  • Up to 6 KW - 1 Phase

Large ASME
Electric

Electric water heater for shipboard marine use large capacity Model MSH
  • Large Capacity
  • 80-5000 Gallon Capacity
  • All KW ratings - 1 or 3 Phase

Heavy Duty
Electric

Electric water heater for shipboard marine use three phase power Model MSE
  • Vertical
  • 6-120 Gallon Capacity
  • 1 or 3 Phase - Up to 58 KW

Tankless
Electric

Electric tankless water heater for shipboard marine use model MTX
  • Tankless Marine Heater
  • Provides 180°F water
  • 11 to 54 KW - 1 or 3 Phase

Naval

Naval shipboard marine electric water heater Hubbell Model 177
  • MIL Spec Navy Heaters
  • Comforms to MIL-H-965
  • Shock and EMI protection

Fully Integrated Package

Turn-key hot water system
  • Customized to your specifications
  • Full featured system ready for your application
   

Immersion Heating
Elements

Electric immersion tubular style heaters
  • Immersion Electric Heaters
  • Flanged or Screw Plugs Types
  • All KW ratings - 1 or 3 Phase

Heat Transfer
Coils

Heat exchanger and heating coil water heaters
  • Immersion Heat Transfer Coils
  • U tube type
  • Range of Materials
   
       
Electric High Capacity
Gas Fired
Steam Fired
Indirect
Storage
Special Purpose
Marine
Elements & Exchangers
Resource Center
Electric booster water heater Model J
Electric booster water heater Model J16
Still have questions? Complete this form
*Name:
*Email:
*State /
Province:
*Comment:

Model J

Electric Booster Heater

For Use in Commercial Kitchens and Restaurants To Supply 180°F Sanitizing Rinse Water

The Hubbell J Model is the longest lasting booster heater available because it utilizes a heavy duty ASME Section VIII designed, constructed and stamped all stainless steel tank which does not require an internal tank lining. Other manufacturers use a non ASME steel tank with an internal lining which is easily eroded in high temperature water and eventually leaves the bare steel tank exposed to the corrosive effects of water. Once this occurs it is only a short time before a steel tank will begin to rust, leak and need replacement.

Hubbell did not stop at improving just the tank design. For improved appearance and longevity the Hubbell booster comes standard with a brushed stainless steel outer jacket and base which is impervious to the corrosive effects of water and looks greatin your kitchen. The Hubbell booster is also equipped as standard with the advanced functionality of an electronic temperature controller to provide accurate, reliable and energy efficient operation while simplifying service work. The Hubbell booster's closed cell foam insulation also improves operating efficiency and reduces the cost of operation.

When you specify and install a Hubbell booster heater, you will have confidence in knowing that the owner will be provided with a long lasting and trouble-free source for 180°F water.


cULUS Listed ANSI NSF 5 ASME
  • Heavy Duty Construction

    • All stainless steel tank construction does not require an internal lining
    • ASME Section VIII stamped construction provides for extended tank life
    • Exterior surfaces including the jacket, base and front cover are all brushed stainless steel for improved appearance and longevity
  • Advanced Design

    • Advanced electronic temperature control with digital display confirms at a glance proper operation and temperature setting
    • Visual indication of exact set point temperature as well as fault conditions provides instant feedback
    • Electronic leak detection system notifies user in the event of an internal water leak
    • Factory packaged resettable circuit breakers (when required) for internal over current protection save time and money compared to one shot fuses
    • A bronze body (not cast iron) pressure reducing valve is factory supplied with each booster
    • Designed for ease of service, no electrical component needs to be removed to replace any other part
    • Screw plug elements with O-ring gasket reduce leakage problems associated with less reliable and more difficult to service flange type heating elements.
  • Reliable

    • Overall dimensions and connections locations are compatible with other popular brands to facilitate direct replacement without modification to the existing plumbing
    • Environmentally friendly CFC/HCFC free closed cell foam insulation minimizes tank heat loss for maximum operating efficiency and reduced operating costs
    • Full ten (10) year (non pro-rated) tank warranty

Why Install A Hubbell Booster Water Heater?

  • Improved Longevity

    The Hubbell booster heater is designed to provide many years of operation. The tank is all stainless steel construction and is designed, constructed and stamped in strict conformance to ASME Section VIII.

  • Lower Operating Costs

    The Hubbell booster tank is encapsulated in environmentally friendly CFC/HCFC free closed cell foam insulation to minimize stand-by heat loss. This high quality insulation reduces heat loss compared to fiberglass type insulation found in other brands. The result is that an average Hubbell booster heater owner can expect to save over 1,400 KW/Hrs compared to ther brands.

  • Reduced Service and Maintenance Costs

    Hubbell has greatly simplified booster heater service and maintenance through numerous advancements in booster design and controls. The Hubbell controller is a major step forward with improved ease of use and service. The digital display provides the owner and technician with an exact set point temperature as well as visual error indication. Because the controller can be set to the exact desired temperature in degrees - there is no more hotter/colder calibration. It also includes a leak detection system to notify the user in the event of an internal leak. For further ease of service and maintenance, all controls are mounted such that when a component is removed for service no other component needs to be removed, and all sensing functions have been consolidated into one probe, which can be replaced without draining the tank. The heating element and sensing probe are straight thread screw types that utilize an O-ring to minimize leakage problems as is common wit flat gaskets and NPT connections.

Model J6 Shown

Model J6 How It Works

Typical Installation Diagrams

Typical J6 Plumbing Connections - Rear View
Typical J16 Plumbing Connections - Front View
Typical J4 Plumbing Connections - Rear View
Typical J3 Plumbing Connections - Front View

Plumbing Notes:

  1. Dielectric unions are recommended for installation in the inlet and outlet piping to prevent electrolysis.
  2. No check valve may be installed in the supply line to the booster.
  3. All shut off valves must be gate or ball valves - not globe valves.
  4. The brass pressure reducing valve with built-in bypass is adjustable from 25 to 75 psi.
  5. To minimize heat loss and maximize efficiency, hot water piping should be insulated.

J Model Standard Accessories

J6 and J16 Boosters

  • T&P Relief Valve
  • Brass pressure reducing valve with built-in bypass
  • (4) NSF approved plastic legs
  • (1) Combination temperature and pressure gauge
  • (2) Dielectric Unions

J4 Boosters

  • T&P Relief Valve
  • Side mounting bracket for securing booster to left or right hand side of dish machine

J3 Boosters

  • T&P Relief Valve
  • 24 volt booster heater interlock adapter

Model Number Selection Chart with Amperage

Base Model KW
Rating
Storage Capacity Full Model Number Listed by Voltage and Phase Amperage Draw by Voltage and Phase
120 V 208 V 240 V 480 V 480 V 600 V 120 V 208 V 240 V 480 V 600 V
1 Φ 1 Φ 3 Φ 1 Φ 3 Φ 3 Φ 1 Φ 3 Φ 1 Φ 1 Φ 3 Φ 1 Φ 3 Φ 3 Φ 3 Φ
J3 2.9 3
Gallons
J32.9A - - - - - - - 24 - - - - - -
5.7 J35.7A - - - - - - - 48 - - - - - -
9.9 - J39.9RS J39.9R - - - - - - 48 28 - - - -
10.4 - J310.4RS J310.4R - - - - - - 50 29 - - - -
11.4 - - - J311.4S J311.4T J311.4T4 - J311.4T6 - - - 48 27 14 11
J4 11.3 4
Gallons
- J411RS J411R - - - - - - 54 31 - - - -
15 - - - J411RS J411R - - - - - - 63 36 18 -
27 - - J427R - J427T J427T4 - - - - 75 - 65 33 -
J6 1 6
Gallons
J61A - - - - - - - 8 - - - - - -
1.5 J61.5A - - - - - - - 13 - - - - - -
2 J62A - - - - - - - 17 - - - - - -
3 J63A - - - - - - - 25 - - - - - -
4 - J64RS - J64S - - J64T4S - - 19 - 17 - - -
5 - J65RS - J65S - - J65T4S - - 24 - 21 - - -
6 - J66RS J66R J66S J66T J66T4 - J66T6 - 29 17 25 14 7 6
7 - J67RS J67R J67S J67T J67T4 - J67T6 - 34 19 29 17 8 7
9 - J69RS J69R J69S J69T J69T4 - J69T6 - 43 25 38 22 11 9
10.5 - J610RS J610R J610S J610T J610T4 - J610T6 - 50 29 44 25 13 10
12 - J612RS J612R J612S J612T J612T4 - J612T6 - 58 33 50 29 14 12
13.5 - J613RS J613R J613S J613T J613T4 - J613T6 - 65 38 56 33 16 13
15 - J615RS J615R J615S J615T J615T4 - J615T6 - 72 42 63 36 18 14
18 - J618RS J618R J618S J618T J618T4 - J618T6 - 87 50 75 43 22 17
24 - J624RS J624R J624S J624T J624T4 - J624T6 - 115 67 100 58 29 23
27 - J627RS J627R J627S J627T J627T4 - J627T6 - 130 75 113 65 33 26
30 - J630RS J630R J630S J630T J630T4 - J630T6 - 144 83 125 72 36 29
36 - J636RS J636R J636S J636T J636T4 - J636T6 - 173 100 150 87 43 35
39 - J639RS J639R J639S J639T J639T4 - J639T6 - 188 108 163 94 47 38
40.5 - J640RS J640R J640S J640T J640T6 - J640T6 - 195 113 169 98 49 39
45 - - J645R J645S J645T J645T4 - J645T6 - - 125 188 108 54 43
54 - - J654R - J654T J654T4 - J654T6 - - 150 - 130 65 52
58.5 - - J658R - J658T J658T4 - J658T6 - - 163 - 141 70 56
J16 1 16
Gallons
J161A - - - - - - - 8 - - - - - -
1.5 J161.5A - - - - - - - 13 - - - - - -
2 J162A - - - - - - - 17 - - - - - -
3 J163A - - - - - - - 25 - - - - - -
4 - J164RS - J164S - - J164T4S - - 19 - 17 - - -
5 - J165RS - J165S - - J165T4S - - 24 - 21 - - -
6 - J166RS J166R J166S J166T J166T4 - J166T6 - 29 17 25 14 7 6
7 - J167RS J167R J167S J167T J167T4 - J167T6 - 34 19 29 17 8 7
9 - J169RS J169R J169S J169T J169T4 - J169T6 - 43 25 38 22 11 9
10.5 - J1610RS J1610R J1610S J1610T J1610T4 - J1610T6 - 50 29 44 25 13 10
12 - J1612RS J1612R J1612S J1612T J1612T4 - J1612T6 - 58 33 50 29 14 12
13.5 - J1613RS J1613R J1613S J1613T J1613T4 - J1613T6 - 65 38 56 33 16 13
15 - J1615RS J1615R J1615S J1615T J1615T4 - J1615T6 - 72 42 63 36 18 14
18 - J1618RS J1618R J1618S J1618T J1618T4 - J1618T6 - 87 50 75 43 22 17
24 - J1624RS J1624R J1624S J1624T J1624T4 - J1624T6 - 115 67 100 58 29 23
27 - J1627RS J1627R J1627S J1627T J1627T4 - J1627T6 - 130 75 113 65 33 26
30 - J1630RS J1630R J1630S J1630T J1630T4 - J1630T6 - 144 83 125 72 36 29
36 - J1636RS J1636R J1636S J1636T J1636T4 - J1636T6 - 173 100 150 87 43 35
39 - J1639RS J1639R J1639S J1639T J1639T4 - J1639T6 - 188 108 163 94 47 38
40.5 - J1640RS J1640R J1640S J1640T J1640T4 - J1640T6 - 195 113 169 98 49 39
45 - - J1645R J1645S J1645T J1645T4 - J1645T6 - - 125 188 108 54 43
54 - - J1654R - J1654T J1654T4 - J1654T6 - - 150 - 130 65 52
58.5 - - J1658R - J1658T J1658T4 - J1658T6 - - 163 - 141 70 56
J16 with 1-1/2" inlet outlet 64 16
Gallons
- - J1664R - - - - - - - 178 - - - -
68 - - - - J1668T J1668T4 - J1666T6 - - - - 164 82 66
81 - - J1681R - J1681T J1681T4 - - - - 225 - 195 98 -
86 - - J1686R - - - - J1685T6 - - 239 - - - 83
88 - - - - J1688T J1688T4 - - - - - - 212 106 -
Notes:
1. The 6, 7, and 9KW models in 208 and 240 volt can be field converted from either 1 phase to 3 phase or from 3 phase to 1 phase
2. All 3 phase units are factory wired as a balanced 3 phase unit.
3. Models are also available in 380, 415, 440 and 575 volt.

Model J6 (1-18 kW) Dimensions

Outline Dimensions

Model J6 (24-58.5 kW) Dimensions

Outline Dimensions

Model J16 (1-58.5 kW) Dimensions

Outline Dimensions

Model J16 (64-88 kW) Dimensions

Outline Dimensions

Model J3 (2.9-11.4 kW) Dimensions

Outline Dimensions

Model J4 (11.3-27 kW) Dimensions

Outline Dimensions

Water Quality Requirements

Recommended water hardness is 4 to 6 grains of hardness per gallon (GPG). Water hardness above 6 GPG should be treated by a water conditoner (water softener or in-line treatment). Water hardness below 4 GPG also requires treatment to reduce potential corrosion. Excessive GPG will result in higher operating and maintenance costs and will reduce product longevity.
Chlorides must not exceed 50 parts per million (ppm). Excessive chlorides will result in metallic corrosion and will reduce product longevity.
Water treatment has been shown to reduce costs associated with deliming the booster as well as reducing metallic corrosion. Product failure caused by these conditions is not covered under warranty. See Warranty for complete details.

Booster Sizing for a LowTemp Dishmachine

Chemical low-temp dishwashers are most effective when supplied with 140°F hot water. This water temperature may not be available due to an undersized primary water heater or local safety code. Hubbell J model boosters can operate as a pre-heater for chemical low-temp dishwashers to provide an adequate supply of 140°F hot water for proper operation. For temperatures other than the factory setting of 185°F, simply set the digital display to your desired temperature.
To properly size a Hubbell booster heater for low temp use:

  1. Determine the required temperature rise; the difference in temperature between your supply water temperature to your booster and your desired hot water temperature out of the booster.
  2. Determine the water usage gallons per hour (GPH) by consulting the dishwasher data plate, literature or NSF listing.
  3. Select the appropriate kW based on 1 and 2 above using either the formula below or the recovery rating.

Booster Sizing Formula

A. Water Usage in GPH _________
B. Supply water temp in °F _________
C. Desired water temp in °F _________
D. Calculate the ΔT (temp rise) by subtracting C - B in °F __________
________ GPH x ________ °FΔT x 0.00244 = _________ KW
Recovery Ratings 1-58.5 kW
KW Rating Recovery Rate in GPH at °F Temperature Rise (ΔT)
20° ΔT 30° ΔT 40° ΔT 60° ΔT 70° ΔT 80° ΔT 110° ΔT 140° ΔT
1 20 14 10 7 6 5 4 3
1.5 31 20 15 10 9 8 6 4
2 41 27 20 14 12 10 7 6
3 61 41 31 20 18 15 11 9
4 82 55 41 27 23 20 15 12
5 102 68 51 34 29 26 19 15
6 123 82 61 41 35 31 22 18
7 143 96 72 48 41 36 26 20
9 184 123 92 61 53 46 33 26
10.5 215 143 107 72 61 54 39 31
12 246 164 123 82 70 61 45 35
13.5 276 184 138 92 79 69 50 39
15 307 205 154 102 88 77 56 44
18 368 246 184 123 105 92 67 53
24 491 328 246 164 140 123 89 70
27 553 368 276 184 158 138 100 79
30 614 409 307 205 175 154 112 88
36 737 491 368 246 211 184 134 105
39 798 532 399 266 228 200 145 114
40.5 829 553 415 276 237 207 151 118
45 921 614 461 307 263 230 167 132
54 1105 737 553 368 316 276 201 158
58.5 1198 798 599 399 342 299 218 171
Recovery Ratings 64-88 kW
64 1310 873 655 437 374 328 238 187
68 1392 928 696 464 398 348 253 199
81 1658 1105 829 553 474 415 301 237
86 1761 1174 880 587 503 440 320 252
88 1802 1201 901 601 515 450 328 257

Recovery

KW Requirement:
________ GPH x ________ °FΔT x 0.00244 = ________ KW
Temperature Rise:
________ KW x 410 ÷ ________ GPH _________ °FΔT
Flow Rate:
________ KW x 410 ÷ ________ °FΔT = __________ GPH
Note: 1 KW will heat 4.1 GPH at a 100°FΔT

Electrical

(KW x 1000 ÷ Volts) ÷ 1.73 = Amps 3 phase
(KW x 1000) ÷ Volts) = Amps 1 phase

Voltage De-Rating Factors

Rated Voltage Applied Voltage De-Rating Factor
600 V 575 V 92%
600 V 550 V 84%
480 V 460 V 92%
480 V 440 V 84%
240 V 230 V 92%
240 V 220 V 84%
240 V 208 V 75%
When the actual supply voltage (applied voltage) is different than the design voltage (rated voltage) the resulting KW output will be affected. Please see the chart for typical voltage de-rating factors, or use the following formula.
(Applied Voltage² ÷ Rated Voltage²) x Rated KW = KW output at applied voltage

The Hubbell Model JTX tankless booster heater is designed for use with conveyor and flight type dishmachines. If the dismachine is not listed, or if the application is other than a conveyor or flight type dishmachine, please contact us directly for assistance.

40°F Rise 70°F Rise
Dishwasher Model Number 6 Gallon 16 Gallon 6 Gallon 16 Gallon
Model J6 Model J16 Model J6 Model J16
ADAMATION
CSL-1390, CA-2, CA-3, CA-4, SLAP 44 J639 J1639 (2) J636 (2) J1636
CA, CA-1 J654 J1654 (2) J645 (2) J1645
ALVEY
FLC-10, SL-2S J166 J169
FLC-12, CL-1, CL-1Turntable, SA-5A J167 J1612
FL-2S J169 J1613
KS-70, KS70M SB J169 J1615
SL-2D J1613 J1618
FLC-36 J1615 J1627
KS-88 J1618 J1630
KS-70-N, KS-88-N J1639
AMERICAN DISH SERVICE
HT-25 J67 J167 J612 J1612
ACD-44, ADC-66 J612 J1612 J624 J1624
BLAKESLEE
UC-21 J66 J166 J612 J1612
D-8 J69 J169 J613 J1613
Series “R” & “ F” -CC, -EE, -LL, -MM, -LLL, -MMM, -PCC, -PEE, -PLL, -PMM J613 J1613 J624 J1624
Series XF-LL, XF-PLL, XF-MM, XF-PMM, XF-EEE, XF-LLL, XF-MMM J618 J1618 J630 J1630
DD-8 J618 J1618 J630 J1630
Series R-L, R-PL, R-M, R-PM, F-L, F-PL, F-M, F-PM (single tank) J636 J1636 J654 J1654
Series XF-L, XF-PL, XF-M, XF-PM, (2) J636 (2) J1636
Series XF-PEE, XF-PLL, XF-PMM, XF-EEE, XF-LLL, XF-MMM (multi tank) J645 J1645 (2) J630 (2) J1630
NOTE: FA (Flight-A-Round) and RA (Rack-A-Round) use comparable “F” listing.
CHAMPION
U-H1, UH-200, UH-200B, U-HB J64 J166 J66 J166
UL-150 J64 J166 J67 J167
UH-150, UH-150B, UH-100, UH-100B, DHB-VS J65 J166 J69 J169
D-H1, D-HB J66 J166 J612 J1612
D-H1T, D-HBT J67 J167 J612 J1612
PP-28 J69 J169 J615 J1615
D-H1C, D-H1TC J69 J169 J618 J1618
66 WSPW, 44-WS, 66-WS J613 J1613 J624 J1624
UC-CW6-WS J624 J1624 J636 J1636
US-CW8-WS J624 J1624 J639 J1639
44, 66 PW, 70FFPW, 80HDPW, 54, 76PW, 80FFPW, 90HDPW, 64, 90FFPW, 100HDPW, 86PW J624 J1624 J645 J1645
40-KB, 44-KB-2-2, 40-KFWB, 40-KPRB, 40-KPRB-2-2, 40PRB-2-3, 60-KB, 60-KB-2-2, 60-KFWB, 60-KFWB-2-2, 60-KPRB, 60-KPRB-2-3, 64KB, 64-KB Corner, 64-KPRB Corner, 64-KPRB, 64-KPRB Corner, 64 Modular, 86 Modular J630 J1630 J654 J1654
44-KB, 44-KB Corner, 44-KPRB, 44-KPRB Corner, 54-KB, 54-KB Corner, 54-KPRB, 54-KPRB Corner, 44 Modular, 66 PW Modular J636 J1636 J658 J1658
UC-CW4 J636 J1636 (2) J636 (2) J1636
UC-C J645 J1645 (2) J636 (2) J1636
UC** Series 6’ Center J645 J1645 (2) J639 (2) J1639
W-6-WS J645 J1645 (2) J645 (2) J1640
CMA DISH MACHINES
CMA-180 J67 J167 J612 J1612
CMA-44H with tank heater, CMA-66H J636 J1636 J645 J1645
HOBART
AM-15F J64 J166 J66 J166
LXiC, LXiGC, LX-18C, LX-30C, LX-40C J64 J166 J67 J166
LX-30, SR24, SR24H J64 J166 J67 J167
LX-18 J65 J166 J69 J169
AM-15, AM-15T J65 J166 J69 J169
WM-5C J66 J166 J69 J169
WM-5 (Without Sump Heater) J67 J167 J612 J1612
AM-14T, AM-14F, AM-14TC J67 J167 J612 J1612
AM-14, AM-14C J69 J169 J612 J1612
AM-12, AM-12C* J69 J169 J618 J1618
UW-50 J1615 J1624
Opti-Rinse Models: C44A, CRS-66A, CCS-66A, CPW-80A, C54A, CRS-76A, CCS-76A, CPW-90A, C64A, CRS-86A, CCS-86A, CPW-100A, C88A, CRS-110A, CCS-110A, CPW-124A J615 J1615 J627 J1627
C-54A, CRS-76A, CPW-90A, CCS-76A J639 J1639 (2) J636 (2) J1636
C-44A, CRS-66A, CCS-66A, CPW-80A, C-64A, CRS-86A, CCS-86A CPW-100A J630 J1630 J654 J1654
C-88A, CRS-110A, CPW-124A, CCS-110A J636 J1636 J654 J1654
Opti-Rinse Models: C44AW, CRS-66AW, CCS-66AW, CPW-80AW J69 J169 J615 J1615
C-44AW, CRS-66AW, CPW-80AW, CCS-66AW J612 J1612 J624 J1624
C-44, CRS-66, CPW-80 J636 J1636 J654 J1654
C-54, CRS-76, CPW-90 J654 J1654 (2) J639 (2) J1639
C-64W, CRS-86W, CPW-100W, C-88W, CRS-110W, CPW-124W, CCS-86W J624 J1624 J636 J1636
C-64, CRS-86, CPW-100 J645 J1645 (2) J636 (2) J1636
FT800W, FT-900W J624 J1624 J639 J1639
FT-600, FT-700 J654 J1654 (2) J639 (2) J1639
FT800 J639 J1639 (2) J639 (2) J1639
FT-900 J636 J1636 J658 J1658
FT800S, FT-900S J639 J1639 (2) J636 (2) J1636
Opti-Rinse Models: FT900-10-FPM, FT900-12-FPM, FT900-6-HTS J624 J1624 J639 J1639
Opti-Rinse Models: FT900S J624 J1624 J624 J1624
UTW-28, UTW-28C J1618 J1636
INSINGER
Commander 18-5, 18-5H, Ensign 40-2 J66 J166 J612 J1612
Admiral 44-4, 66-4 J624 J1624 J636 J1639
Speeder 64, 86-3, Century (all) J624 J1624 J645 J1645
Trac 321, Trac 321-2/RPW J627 J1627 J645 J1645
Trac 878 J624 J1624 J636 J1636
Clipper (all), R106-2, Super 106-2 J627 J1627 J645 J1645
Defender J636 J1636 J654 J1654
Master (all) J636 J1636 J658 J1658
CA-3 J169 J1624
DA-3 (2) J169 (2) J1624
JACKSON
JPX-140, JPX-160, JPX-200, JPX-200/2, TSC-44, TSC-66 J64 J166 J64 J166
H-24, HZ-24, JP-24, JPX-300H, JPX-300HN, JPX-300N, M-24BF J64 J166 J65 J166
JP-24B, JP-24F, JP-24BF J64 J166 J66 J166
24B Series J64 J166
10AB, 10APRB J65 J166
200, Huey 165, Supra-Q2020 J66 J166 J69 J169
100B, 100PRB, 150B, 150PRB J69 J169
Tempstar SDS J66 J166 J612 J1612
10A, 10APRB, 10APRB-M, 10U, 300X, 300XN, ES-18, ES-18HT, E-xxion, TS-57, Tempstar, Tempstar 300N, Tempstar 300X, Tempstar 300XG, Tempstar GPX J66 J166 J612 J1612
Inferno, Omega HT J67 J167 J612 J1612
PH-HT, Performer, TempStar HH, TempStar HH/GPX, TempStar HH/S J67 J167 J613 J1613
200B J66 J166
100 J612 J1612 J624 J1624
150 J612 J1612 J618 J1618
TS-44, TS-66 J624 J1624 J636 J1636
AJ-64, AJ-86, AJ-100, JFT, JFT Flight Type, JFT-G, JFT-S J624 J1624 J639 J1639
ES-8000, PA-C4, WH-44, WH 66 J624 J1624 J645 J1640
64CE, 86 CERPW J627 J1627 J639 J1639
AJ-54, AJ-76, AJ-90 J630 J1630 J654 J1654
44CE*, 66 CERPW J630 J1630 J654 J1654
54CE, 76 CERPW J636 J1636 (2) J630 (2) J1630
AJ-44, AJ-66, AJ-80, ES-4400, ES-6600 (ECOLAB/JACKSON) J624 J1624 J645 J1645
NOTE 1: Model 44CE with serial no.1999 or below requires larger booster than listed.
KNIGHT EQUIPMENT
KLE-112-HL J67 J167 J612 J1612
MEIKO
K-44, K-66, K-80 J624 J1624 J636 J1636
K-54, K-76, K-90, K-64, K-86, K-100 J624 J1624 J645 J1645
METALWASH/INTEDGE
FW4 J612 J1612 J618 J1618
RS-30A, RS-28L J1615 J1624
RT-74, RT-60, RT-42B, RT-42BC J1627 J1640
RS-2R J1630 J1645
STERO
SCT-44-10-LW, SCT-44-LW, SCT-66S-LW, SCT-76S-LW, SCT-76SC-LW, SCT-90S-LW J612 J1612 J624 J1624
SC-1-2-4-LW, SC-1-6-4-LW, SC-1-6-4-LW, SC-2-4-LW, SC-5-6-4-LW, SC-6-4-LW J624 J1624 J645 J1645
SCT-64, SCT-86S, SCT-94S, SCT-94SC J624 J1624 J639 J1639
SCT-108S, SCT-108SC, SCT-76, SCT-94SM J627 J1627 J654 J1654
SC-6-4, SCT-44, SCT-44-10, SCT-44-10, SCT-66S, SCT-76S, SCT-90S J630 J1630 J654 J1654
SCT-120S, SCT-120SC, SCT-120SM, SCT-150SM J636 J1636 J658 J1658
STW-110, SC-1-2-7-4, SC-1-6-3-4, SC-1-6-7-4, SC-2-7-4, SC-5-2-7-4, SC-5-6-3-4, SC-5-6-7-4, SC-6-3-4, SC-6-7-4 J639 J1639 (2) J636 (2) J1639
SC-1-2-4, SC-1-6-4, SC 2-4, SC-5-2-4, SC-5-6-4 J645 J1645 (2) J636 (2) J1645
SCT-44-10-SC-1-3-4, SCT-44-10-3-4, SCT-44-SC-1-3-4, SCT-44-SC-3-4, SCT-54-SC-1-3-4, SCT-54-SC-3-4, SCT-76S-SC-3-4 J645 J1640 (2) J636 (2) J1636
STPC (Four Tank) J624 J1624 J639 J1639
STPCW (Four Tank) J624 J1624 J645 J1640
STPC J627 J1627 J654 J1654
STPCW J636 J1636 (2) J630 (2) J1630
SCBT J645 J1640 (2) J636 (2) J1636
SF-1RA, SC20-1 J67 J167 J612 J1612
SF-2RA, SF-2DRA, SD-2RA, SDRA, SDRA-PACK J612 J1612 J618 J1618
SCT-54, SCT-76SM J636 J1636 J658 J1658
SCT-76, SCT-80, SCT-94, SCT-108, SCT-120 J645 J1645 J658 J1658
U-31-A, U-31-AC J1618 J1636
U-31-A2 J645 J1645 (2) J636 (2) J1636
STBUW-14 J658 J1658 (2) J654 (2) J1654
SC-2-3-4, SC-5-2-3-4 J630 J1630 (2) J627 (2) J1627
SC20-2 J612 J1612 J624 J1624
SC-2-8, SC-2-9, SC-1-2-8, SC-5-6-8, SC-6-8, SC-6-9, SC-1-6-8, SC-5-6-9, SC-5-2-9, SC-1-6-9, SC-5-2-8 J618 J1618 J636 J1636
NOTE 1. FRC and FR (Fast Rack Series) use comparable "C" line listing.
NOTE 2. Model AM-12 with serial no. 12-067-357 or below and model AM-12C with serial no. 12-067-537 or below require slightly larger booster heater than listed.
NOTE 2. C models with serial no. 85-1041605 or greater use Opti-Rinse

This selector chart is based upon 40°F and 70°F temperature rises, and 20psi flow pressure and minimum rinse cycle timer setting in NSF listing.

All booster heaters are rated at 100% of the capacity of the dishwasher as recommended by the National Sanitation Foundation. Where make-up water for the wash tank is provided from the final rinse supply, chart recommendations are based upon this additional demand (not exceeding 2 GPM) as required by NSF.

Optional Equipment

  • Slide Brackets:
    Available for the J6 model only, these brackets allow for mounting the booster heater under a counter.
  • Shock Absorber:
    Reduce the harmful pressures resulting from quick closing dishwasher solenoid valves by installing a shock absorber between the booster and the dishwasher.
  • Tamper Resistant Package:
    For prison and other secure facilities a tamper resistant pacakge is available with all hardware tamper resistant type. Includes standard plastic legs unless otherwise specified.
  • Protective Cover:
    Keep your Hubbell booster free from dirt, debris, chemicals and execessive water with this removable form fitted protective cover. Velcro fasteners make it easily installed and simple to remove when service is required. Clear window allows visibily of Hubbell booster digital display. (J6 and J16 Boosters only)
  • Alternate Legs:
    Please specify type: Nickel plated die cast, stainless steel, stainless steel with flanged base for floor mounting
  • 24 Volt Heater Interlock Adapter:
    An optional plug adapter that interlocks the heater via a 24-Volt signal through the J1 connector on the control board (standard on the J3)
  • Water Treatment System:
    Provide superior mineral scale prevention and corrosion control by feeding a special blend of scale control compounds into the hot water stream before the booster. The in-line system to include a clear cartridge and determine when it needs a replacement without the need to open the system.
  • Alternative Voltages:
    Hubbell booster heaters are available in alternate voltages including 380, 415, 440, 575 volt
  • Low Temperature Interlock:
    This device is built into the booster and monitors water temperature and will trip an SPDT relay when water temperature drops below a set point (150 - 180°F) thereby preventing final rinse from activating
  • Remote Alarm Adapter:
    This device installs into the Hubbell controller and provides remote alarm capability to indicate a reset fault condition. Common/N.O./N.C. rated 220 VDC, 250 VAC, 2 amp max.
  • Remote Control Panel:
    This device allows you to install the booster in one location and have complete control of it (on/off, temperature adjustment, reset and temperature indication) from another location (200 feet maximum). Remote control panel is 5" x 2" x 3" and NEMA 4 rated.

J6 Slide Bracket Detail

Model J6 Optional Slide Bracket Detail

Model Number Designation J



Step 1
Model:
J = Vertical

Step 2
Storage Capacity:
3, 4, 6, 16 U.S. Gallons
Step 3
KW:
1-88 KW

Step 5
Voltage/Phase/Hz:
1 Φ Voltages
A = 120-1-60
RS = 208-1-60
S = 240-1-60
W = 277-1-60
T4S = 480-1-60
3 Φ Open Delta
R = 208-3-60
T = 240-3-60
T3 = 380-3-50/60
T7 = 415-3-50/60
T5 = 440-3-60
T4 = 480-3-60
T6 = 600-3-60

Example:

J164T4S

Model J booster with 16 gallons storage capicity and 4.5 KW rating. Booster operates at 480V, three phase, 60 Hz power.

Model J Specific Questions

Can the Hubbell booster be used in a low temp application?

Yes. The Hubbell booster heater includes an advanced electronic temperature controller which does not require special calibration for a low temp application. In comparison, other booster heater brands that use a mechanical thermostat need to specify when the booster is for a low temp application so the thermostat can be specially calibrated at the factory.

What data is required when sizing a booster heater to a dishmachine?

Essential information is the temperature of the incoming water from the primary water source, desired temperature rise and the make and model of the dishmachine. If the dishmachine is unknown, then you must provide gallons per hour (GPH) required by the dishmachine for the final rinse cycle. The formula to determine the amount of kW the booster heater needs to be is as follows: GPH x °F Temp Rise x 0.00244 = kW required.

Can I convert a Hubbell booster from 1 phase to 3 phase, or vise versa?

Only Hubbell 6, 7 or 9kW models in 208v or 240v can be field converted from single phase to three phase power or from three phase to single phase power. All Hubbell boosters when wired for three phase are balanced. Hubbell does not recommend installing any booster heater that is an unbalanced three phase. All other kW Models cannot be field converted.

What does 3 phase Open Delta wiring mean to me?

Without getting into a lengthy discourse on electricity, the simple answer is that any water heater internally wired in a 3 phase open delta configuration is unbalanced, meaning that the amperage drawn by one of the three legs is high and unequal to the other two legs. This unbalanced water heater can have a detrimental effect on a buildings power system and therefore needs to be carefully understood before you install a water heater configured for 3 phase open delta. It should be noted that the branch circuit protection (i.e. circuit breaker) servicing a 3 phase open delta water heater needs to be sized for the high amperage leg. The Hubbell model E is available up to a maximum of 12kw in 3 phase open delta wiring. Alternatively, the Hubbell model SE is a balanced 3 phase water heater, meaning that all three legs draw equal amperage. The Model SE is available up to 58kw click here details Model SE

Do I want the 6 or 16 gallon size?

The J6 is a 6 gallon tank and the J16 is a 16 gallon tank. The 16 gallon model has a larger footprint, which might be considered by some to be easier to service. However, the 6 gallon model is lower initial cost compared to the 16 gallon model. Otherwise, either model is acceptable for use when both are shown in the selection chart.

General Questions

Where can I purchase a Hubbell water heater?

There are numerous ways to purchase a Hubbell water heater depending upon the model you desire and your geographic location. The easiest way is to contact Hubbell directly at 800-647-3165 and ask for the sales department where you will be directed to either our local representative or our order entry department for quick and easy ordering.

Where can I purchase replacement parts?

Parts are available for your Hubbell water heater direct from the factory. Please call 800-647-3165 and ask for our parts department. Please have your model and serial number handy.

I don't see the size or feature I need, what do I do?

Hubbell has more than 35 product families available in over 4,000,000 configurations. There are numerous features, configurations and ratings we provide but for practical reasons are are not listed in the sales brochure. If you have a specific requirement and you do not see it in the brochure, please contact a Hubbell Sales Engineer...chances are we have what you need.

What should I know about Legionella disease?

Legionella is the bacteria responsible for Legionnaire’s Disease, an acute bacterial infection of the lower respiratory tract. This bacterium was first identified in 1977 by the Centers for Disease Control as the cause of an outbreak of pneumonia that caused 34 deaths at a 1976 American Legion Convention in Philadelphia. Pontiac Fever is a less severe, non-pneumonia, flu-like disease that is associated with and likely caused by Legionella bacteria. Legionella is a fairly common water bacterium and has been found to exist widely in many surface water sources including lakes, rivers, streams and ponds. It can also be found in ground water sources and some soils. At the levels found in these naturally occurring sources it typically does not pose a threat to public health. When the bacterium enters a domestic water system it can find an ideal host environment of warm water temperatures (105-115°F), stagnant water areas (isolated storage tanks and dead-end piping legs) and ample food sources (sediment, scale, deposits and biofilm). Under these conditions Legionella can rapidly colonize, forming higher concentrations that can pose the public health threat of Legionnaire’s Disease. There are many methods of controlling colonization of Legionella bacteria. However, a widely accepted and preferred method is to maintain the hot water system storage temperature continually at or above 140°F. Unfortunately, the elevated temperature necessary to minimize the growth of and kill Legionella bacteria has the potential to cause serious thermal shock and scalding injuries. As such, many plumbing engineers will specify that the water heater be set to maintain water temperatures at 140°F or higher to reduce the risk of Legionella, but then specify the appropriate mixing valve to ensure safe delivery of hot water to the fixtures. For a more thorough discussion of Legionella please go to here and the following link to the US Department of Labor OSHA information regarding Legionnaires’ Disease OSHA here

My question is not found in these FAQ’s, where do I look next?

Check out the Hubbell Product Center at Here for a complete listing of all technical documentation available by model. Get easy access to Installation, Operation & Maintenance manuals, Sales Brochures, Service Bulletins, Wiring Schematics, Parts Breakdowns and various other technical documents related to the full line of Hubbell water heaters. Or, if you prefer, please call us at 800-647-3165 and ask to speak to a Sales Engineer.

Downloads

Many of our products literature is available online for download. To open these files, a PDF viewer is required. If you do not have one, Adobe provides Acrobat Reader free of charge for viewing only. Use this link to download Acrobat Reader. You may also choose to download the file to your PC for future reference or printing. On most operating systems, simply right-click on the links below, choose "Save target as..." or "Save link as...", choose a location and it will save the document to your computer for future reference.

Model J Specific Questions

My question is not found in these FAQ’s, where do I look next?

Check out the Hubbell Product Center at Here for a complete listing of all technical documentation available by model. Get easy access to Installation, Operation & Maintenance manuals, Sales Brochures, Service Bulletins, Wiring Schematics, Parts Breakdowns and various other technical documents related to the full line of Hubbell water heaters. Or, if you prefer, please call us at 800-647-3165 and ask to speak to a Sales Engineer.

Where can I purchase replacement parts?

Parts are available for your Hubbell water heater direct from the factory. Please call 800-647-3165 and ask for our parts department. Please have your model and serial number handy.

More Model J Tech Support Questions...             Training Center             Model J Service Videos

For Further Assistance Please Contact a Hubbell Tech Support Rep.

Sam Wellington
samw@hubbellheaters.com
203-378-2659 x136
D.J. Dineson
djdineson@hubbellheaters.com
203-378-2659 x125
Hubbell Heaters
45 Seymour Street
P.O. Box 288
Stratford, CT 06615-0288
Tel: 203-378-2659
Fax: 203-378-3593
Product Center
Hubbell Binder

View our current digital materials available in our resource center.

To Product Center  Bullet Point