Electric Low Capacity

Model E

Electric cement lined water heater Model E
  • Light Duty
  • 6 - 120 Gallon Capacity
  • Up to 12KW - 1 Phase or 3 Phase

Model HE / HSE

Electric horizontal ceiling hung water heater Model HE/HSE
  • Horizontal, Ceiling Hung
  • 20 or 30 Gallon Capacity
  • Up to 20 KW - 1 or 3 Phase

Model PBX

Hybrid electric heat pump water heater Model PBX
  • Heat Pump Water Heater
  • 40 - 120 Gallon Capacity
  • 1 or 3 Phase

Model CE 110

Point-of-use electric water heater Model CE110
  • Point-of-Use
  • 1 Gallon Capacity
  • 1000 or 450 Watts - 1 Phase

Model Tankless

Electric tankless point-of-use water heater Model R
  • Whole House / Point-of-Use
  • Availabe 3 thru 27 KW - 1 Phase

Model J

Electric booster water heater Model J
  • Booster Heater
  • Provides 180°F water
  • Up to 88 KW - 1 or 3 Phase

Model JTX

Electric tankless booster heater Model JTX
  • Tankless Booster Heater
  • Provides 180°F water
  • 11 to 54 KW - 1 or 3 Phase

Model SE

Commercial heavy duty electric storage water heater Model SE
  • Light Duty
  • 6-120 Gallon Capacity
  • Up to 58 KW - 3 Phase

Model HX / TX

Electric tankless water heater Model TX
  • Tankless Commercial
  • Highly efficient tankless
  • Up to 54 KW - 1 or 3 Phase

Model SH & H

Large capacity electric storage tank water heater Model SH
  • Large Capacity
  • 80-5000 Gallon Capacity
  • All KW ratings - 1 or 3 Phase
     

Model GX

Gas tankless water heater Model GX
  • Commercial Gas Tankless
  • Integrated Pump
  • 200,000 and 250,000 BTUs

Model GXT

Condensing gas storage tank water heater Model GXT
  • Integrated Tank with Tankless
  • Hydrastone Cement
  • 200,000 to 250,000 BTUs

Model DGX

DI/RO gas fired tankless water heater Model DGX
  • DI/RO Water Heater
  • Gas Tankless
  • 199,950 and 250,000 BTU

Model JBX

Condensing gas tankless booster water heater Model JBX
  • Gas Tankless Booster
  • For Commercial Kitchens
  • 150,000 / 200,000 / 250,000 BTU

Model GSE

Condensing gas storage tank water heater Model GXT
  • Gas Storage Tank
  • Hydrastone Cement
  • 200,000 to 250,000 BTUs
   

Model ST

Steam fired water heater large capacity Model ST
  • Storage Type
  • 80-5000 Gallon Capacity
  • ASME Stamped

Model STX

Semi-Instantaneous Steam Fired Water Heater Model STX
  • Semi-Instantaneous
  • Space saving design
  • Provides 10,500 GPH

Model PS

Storage tank steam fired water heater Model PS
  • Light Duty
  • 80-120 Gallon Capacity
  • For low demand/recovery

Model F

Instantaneous steam fired water heater Model F
  • Instantaneous
  • 7 Sq. Ft. of floorspace
  • Up to 120 GPM
     

Model BWX

Indirect fired semi-instantaneous water heater Hubbell Model BWX
  • Semi-Instantaneous
  • Vertical or Horizontal
  • ASME Stamped

Model BW

Indirect fired storage tank water heater Hubbell Model BW
  • Storage Type
  • Vertical or Horizontal
  • 80-5000 Gallon Capacity

Model Transflow

Indirect fired storage tank water heater model T Transflow
  • Indirect Fired
  • 30-120 Gallon Capacity
  • Utilizes boiler water

Model SLN

Solar water heater Model SLN
  • Solar Heater
  • Vertical Storage Type
  • 30-120 Gallon Capacity
       

Model CR

Electric circulation heater Hubbell Model CR
  • Circulation (Instantaneous)
  • Heavy Duty Construction
  • 25-1600 KW - 1 or 3 Phase

Model ER

Electric hazardous location water heater Model ER
  • Hazardous Location
  • 10-120 Gallon Capacity
  • Up to 58 KW - 1 or 3 Phase

Model V

Electric process industrial water heater Model V
  • Process Systems & Industrial
  • ASME Stamped
  • Up to 88 KW - 1 or 3 Phase

Model ETX

Electric tankless safety shower water heater Model ETX
  • Tankless Emergency Tepid Water
  • NEMA 4 Standard
  • Up to 88 KW - 1 or 3 Phase

Model HD

DI/RO electric hot water heater Model HD
  • RO/DI Water Heater
  • Point-of-Use Heater
  • Up to 88 KW - 1 or 3 Phase

Model D

DI/RO electric hot water heater Model D
  • RO/DI Water Heater
  • 1-120 Gallon Capacity
  • Up to 88 KW - 1 or 3 Phase

Model EMV

Electric safety shower water heater Model EMV
  • Emergency Tepid Water
  • Fully packaged system
  • Integrated mixing valve

Packaged Skid

Model Packaged Skid
  • Customized to your specifications
  • Full featured system ready for your application

Model ME

Electric water heater for shipboard marine use single phase power Model ME
  • Light Duty
  • 6-120 Gallon Capacity
  • Up to 6 KW - 1 Phase

Model MSH

Electric water heater for shipboard marine use large capacity Model MSH
  • Large Capacity
  • 80-5000 Gallon Capacity
  • All KW ratings - 1 or 3 Phase

Model MSE

Electric water heater for shipboard marine use three phase power Model MSE
  • Vertical
  • 6-120 Gallon Capacity
  • 1 or 3 Phase - Up to 58 KW

Model MTX

Electric tankless water heater for shipboard marine use model MTX
  • Tankless Marine Heater
  • Provides 180°F water
  • 11 to 54 KW - 1 or 3 Phase

Model 177

Naval shipboard marine electric water heater Hubbell Model 177
  • MIL Spec Navy Heaters
  • Comforms to MIL-H-965
  • Shock and EMI protection

Integrated Skid

Turn-key hot water system
  • Customized to your specifications
  • Full featured system ready for your application
   

Heating Elements

Electric immersion tubular style heaters
  • Immersion Electric Heaters
  • Flanged or Screw Plugs Types
  • All KW ratings - 1 or 3 Phase

Heat Transfer Coils

Heat exchanger and heating coil water heaters
  • Immersion Heat Transfer Coils
  • U tube type
  • Range of Materials
   
       
Electric High Capacity
Gas Fired
Steam Fired
Indirect
Special Purpose
Marine
Elements & Exchangers
Resource Center
Commercial heavy duty electric storage water heater Model SE
Still have questions? Complete this form
*Name:
*Email:
*State /
Province:
*Comment:

Model SE

Commercial Electric Water Heater

6-120 Gallon Capacity, up to 58 KW in all Three Phase Voltages, Over 6 KW in all Single Phase Voltages

The Hubbell Model SE water heater incorporates a number of features not found in other conventional heaters which makes it better suited to resist the highly corrosive effects of hot water. The heart of a Hubbell water heater is a superior storage vessel which utilizes a specially formulated Hydrastone cement lining, solid copper-silicon threaded tank openings and a built-in trap device, all of which ensure a longer lasting and energy efficient water heater.

When you specify and install a Hubbell Model SE, you will have confidence in knowing that the owner will be provided with a long lasting, trouble-free source for hot water.

Learn More About Hydrastone Cement Lining

cULUS Listed
  • Heavy Duty Construction

    • Hydrastone cement lining provides longer tank life
    • Copper-silicon alloy tappings cannot rust or corrode
    • High impact composite jacket cannot rust or corrode and elimantes damage during installation and transit
  • High Efficiency

    • Polyurethane foam insulation reduces heat loss
    • Built-in heat trap lowers operating costs
  • Wide Selection

    • Built to meet your exact needs
    • Numerous options available for specialized applications
  • Reliable

    • Full five (5) year Non Pro-rated tank warranty is standard
    • Full ten (10) year Non Pro-rated tank warranty can be specified for extended protection

How It Works goes here!

Model SE Water Heater Specifications

Capacities: 6 thru 120 Gallons
Orientation: Vertical
Voltages: 208 thru 600 Volt
Phase: 1 Φ and 3 Φ
Inlet Size:
Below 45 KW: 3/4" Female NPT
45 KW and over: 1 1/2" Male NPT
Outlet Size:
Below 45 KW: 3/4" Male NPT
45 KW and over: 1 1/2" Male NPT
Drain Size: 3/4" GHT
Relief Valve Size: 3/4" Female NPT
Relief Valve Type: T&P, 210°F, 150 psi
Hi-Limit: 190°F Manual Reset
Thermostat Range:
Surface: 110-170°F
Immersion: 100-190°F
Design WP: 150 psi
Design TP: 300 psi
Elements: Incoloy Sheathed
Insulation:
Model SE: 2" Polyurethane Foam
Model SM: 3" Polyurethane Foam
Tank Warranty:
Standard: 5 Year Non Pro-Rated
Optional: 10 Year Non Pro-Rated
Electrical Warranty: 1 Year
Jacket: High Impact Colorized Composite
Color: White and Black

Standard Equipment

  • Non-ferrous solid copper-silicon threaded openings for maximum corrosion resistance
  • Magnetic contactor(s) are heavy duty resistive load type rated for 200,000 cycles
  • Incoloy sheathed immersion heating elements
  • Built-in heat trap to improve operating efficiency (3/4" inlet/outlet models only)
  • Surface thermostat 110-170°F range
  • Immersion thermostat (100-190°F) furnished as standard when required due to high recovery versus storage ratio.
    On 6-30 gallon heaters 5 KW and above
    On 40 and 50 gallon heaters over 8 KW
    On 65 gallon heaters over 12 KW
    On 80-120 gallon heaters over 15 KW
  • Surface safety hi-limit cut out with manual reset button (190°F)
  • Immersion safety hi-limit cut out with manual reset button (Standard on heaters 45 KW and above)
  • 1 1/2" Male NPT inlet/outlet connections (Standard on heaters 45 KW and above)
  • ASME/CSA rated temperature and pressure relief valve set at 150 psi, 210°F
  • 2" thick polyurethane foam insulation
  • High impact non-corroding colorized composite protective jacket
  • Cold water inlet diffuser with drain valve

Outline Dimensions

Outline Dimensions

Model SE Dimensional Data

Storage Capacity (Gallons) Base Model Number Maximum KW Input Dimensions (Inches) Shipping Weight (lbs.) Optional 3" Foam Insulated Models SM
Diameter
"A"
Height
"B"
Floor to Inlet
"C"
Floor to T&P
"D"
Storage Capacity (Gallons) Diameter "A"
6 SE06 3 15 17.5 5 12.5 115 6 N/A
10 SE10 10 20 21 7 15 145 10 22.75
20 SE20 20 20 33 7 27 175 20 22.75
30 SE30 20 20 41.5 7 34 210 30 22.75
40 SE40 20 20 58.75 7 51 265 40 22.75
50 SE50 20 22.75 51 7 43 295 50 26
65 SE65 58 26 48 8 40 335 65 28
80 SE80 58 26 58 8 51 410 80 28
100 SE100 58 26 69.5 8 62 425 100 28
120 SE120 58 28 69.25 8 62 495 120 30
30 SEU30 20 22.75 33 7 24 215 30 26
40 SEU40 58 26 33 7 24 295 40 28
50 SEU50 58 28 36 7 27 300 50 30
Note: Under counter Models SEU40 and SEU30 hot water oulet is located on the side.

Formulas & Charts goes here!

Optional Equipment

  • Full 10 Year Non Pro-Rated tank warranty
  • Low voltage control circuit (fused) transformer
  • Electronic solid state low water cut off
  • Power circuit fusing
  • Immersion thermostat (specify 100-190°F or 30-110°F Range)
  • Immersion adjustable safety hi-limit cut out with manual reset (100-240°F)
  • Solid state electronic digital display temperature controller with multi stage temperature control, low water cut out, and leak detection sensor
  • NSF approved floor mount 6" high legs
  • UL EPH/ANSI NSF tank lining
  • Storage tank constructed from (304L or 316L stainless steel, copper-nickel) for maximum tank life
  • ASME tank construction
  • 1 1/2", 2" Male NPT brass inlet and outlet water connections (heat trap not available)
  • Foam insulation 3" thick for improved operating efficiency
  • Combination temperature and pressure gauge; 2 1/2" dial, 70-250°F, 0-200 psi
  • Upper and lower heating element design for quicker recovery
  • Built-in circuit breaker with or without shunt trip protection
  • Built-in non-fused On/Off disconnect switch
  • Electro-mechanical 7-day time clock with battery back-up
  • Building Management System (BMS) control package for remote operating/alarm capability
  • Horizontal construction, ceiling hung or base mounted
  • NEMA 4 weather resistant construction for installation in "wet" areas
  • Steel wall shelf for 6-40 gallon models
  • Integrally welded seismic attachment points

Model Number Designation SE



Step 1
Model:
SE = 2" Foam
Insulation
SM = 3" Foam
Insulation
SEA = Pressure Vessel
is ASME Stamped
Step 2
Storage
Capacity:

6 - 120
U.S. Gallons
-
Step 3
Upper KW:
Element bank
0-58 KW
(typically 0)
Not available in
6, 10, 20 Gallon
capacity heaters
-

Step 4
Lower KW:
Element bank
1-58 KW

Step 5
Tank:
SL = Hydrastone
Cement Lined Tank
CN = Solid 90/10
Copper Nickel tank
SS = Solid type
304L or 316L
stainless steel tank

Step 6
Voltage/Phase/Hz:
RS = 208-1-60
R = 208-3-60
S = 240-1-60
T = 240-3-60
W = 277-1-60
T3 = 380-3-50/60
T7 = 415-3-50/60
T5 = 440-3-60
T4 = 480-3-60
T4S = 480-1-60
T6 = 600-3-60

Example:

SE120-0-18SLT4

Model SE with a 2" foam insulated storage tank of 120 Gallons with 18 KW in the lower element bank. Storage tank is lined with Hydrastone cement and the electrical controls operate at 480 V, three phase, 60 Hz power.

Model SE Submittal Drawing
Printable Version

Model SE Specific Questions

Which is better for me, a tankless or storage type water heater?

It depends. A tankless water heater is sometimes referred to as a Point-of-Use (POU) or instantaneous water heater. Due to the relative small physical size of a tankless water heater compared to a storage tank water heater, a tankless option can be advantageous from a space saving perspective and can sometimes be installed closer to where you want hot water (hence the term POU). However, tankless heaters are not suited for many applications, so it is critical that before choosing to go tankless you have carefully considered all of the factors that sometimes make the tankless option more complicated and risky compared to a storage type water heater. In particular, you should understand the operational characteristics, maintenance requirements, reparability, and sometimes significant installation requirements of a tankless water heater before making a decision. Tankless units do not store heated water like a storage type water heater; they only heat water as there is demand and therefore must be sized to meet the maximum flow for the application. In some cases a tankless water heater may improve operating efficiency, but possibly at the expense of user comfort. Hubbell tankless water heaters are available in Electric Tankless or Gas Tankless

How does the heat trap work?

The Hubbell water heater is constructed with a heat trap installed within the water heater’s hot water outlet connection. This device helps prevent heat from escaping through the storage tank’s hot water outlet during standby periods, resulting in improved operating efficiency. The heat trap is constructed from a specially designed bronze nipple with an internal floating ball that during standby periods of no flow settles and closes off the storage tank thereby preventing thermal conduction of hot water radiating through the hot water outlet.

What is the max water temperature setting?

The Hubbell cement lined tank is suitable for storing water up to 194°F. However, it should be noted that your water heater will likely require optional control accessories to achieve this temperature, but there is no concern regarding the ability of the lining to withstand this temperature. Additionally, there are numerous safety concerns that must be considered when storing water at elevated temperature, please consult factory.

When should I specify an immersion thermostat?

An immersion thermostat should be specified when the desired operating temperature either is below 110F or above 170F, or the water heater is to be used in an unusual application that is outside of the normal operating parameters of a typical domestic water heater. Otherwise, the type of thermostat (surface or immersion) is determined by Hubbell as is appropriate for the kw and storage tank size of the water heater.

Why is Hydrastone Cement a better choice over glass lining?

Cement lining provides guaranteed 100% coverage with a minimum thickness of 0.5” over all internal tank surfaces. In comparison, glass lining is approximately 0.005” thick and includes imperfections, pinholes and variation in coverage thickness resulting in portions of unprotected steel tank exposed to corrosion. In an attempt to compensate, glass lined tanks include a sacrificial anode in an effort to slow down the corrosion of the tank. Cement lined tanks on the other hand do not require an anode due to the integrity of the lining. As such, a cement lined tank will far outlast a glass lined tank. For a more complete explanation of the benefits of the Hubbell cement lining please click on the following link Cement Lining

General Questions

Where can I purchase a Hubbell water heater?

There are numerous ways to purchase a Hubbell water heater depending upon the model you desire and your geographic location. The easiest way is to contact Hubbell directly at 800-647-3165 and ask for the sales department where you will be directed to either our local representative or our order entry department for quick and easy ordering.

Where can I purchase replacement parts?

Parts are available for your Hubbell water heater direct from the factory. Please call 800-647-3165 and ask for our parts department. Please have your model and serial number handy.

I don't see the size or feature I need, what do I do?

Hubbell has more than 35 product families available in over 4,000,000 configurations. There are numerous features, configurations and ratings we provide but for practical reasons are are not listed in the sales brochure. If you have a specific requirement and you do not see it in the brochure, please contact a Hubbell Sales Engineer...chances are we have what you need.

What should I know about Legionella disease?

Legionella is the bacteria responsible for Legionnaire’s Disease, an acute bacterial infection of the lower respiratory tract. This bacterium was first identified in 1977 by the Centers for Disease Control as the cause of an outbreak of pneumonia that caused 34 deaths at a 1976 American Legion Convention in Philadelphia. Pontiac Fever is a less severe, non-pneumonia, flu-like disease that is associated with and likely caused by Legionella bacteria. Legionella is a fairly common water bacterium and has been found to exist widely in many surface water sources including lakes, rivers, streams and ponds. It can also be found in ground water sources and some soils. At the levels found in these naturally occurring sources it typically does not pose a threat to public health. When the bacterium enters a domestic water system it can find an ideal host environment of warm water temperatures (105-115°F), stagnant water areas (isolated storage tanks and dead-end piping legs) and ample food sources (sediment, scale, deposits and biofilm). Under these conditions Legionella can rapidly colonize, forming higher concentrations that can pose the public health threat of Legionnaire’s Disease. There are many methods of controlling colonization of Legionella bacteria. However, a widely accepted and preferred method is to maintain the hot water system storage temperature continually at or above 140°F. Unfortunately, the elevated temperature necessary to minimize the growth of and kill Legionella bacteria has the potential to cause serious thermal shock and scalding injuries. As such, many plumbing engineers will specify that the water heater be set to maintain water temperatures at 140°F or higher to reduce the risk of Legionella, but then specify the appropriate mixing valve to ensure safe delivery of hot water to the fixtures. For a more thorough discussion of Legionella please go to here and the following link to the US Department of Labor OSHA information regarding Legionnaires’ Disease OSHA here

My question is not found in these FAQ’s, where do I look next?

Check out the Hubbell Product Center at Here for a complete listing of all technical documentation available by model. Get easy access to Installation, Operation & Maintenance manuals, Sales Brochures, Service Bulletins, Wiring Schematics, Parts Breakdowns and various other technical documents related to the full line of Hubbell water heaters. Or, if you prefer, please call us at 800-647-3165 and ask to speak to a Sales Engineer.

Downloads

Many of our products literature is available online for download. To open these files, a PDF viewer is required. If you do not have one, Adobe provides Acrobat Reader free of charge for viewing only. Use this link to download Acrobat Reader. You may also choose to download the file to your PC for future reference or printing. On most operating systems, simply right-click on the links below, choose "Save target as..." or "Save link as...", choose a location and it will save the document to your computer for future reference.

Model SE Specific Questions

My question is not found in these FAQ’s, where do I look next?

Check out the Hubbell Product Center at Here for a complete listing of all technical documentation available by model. Get easy access to Installation, Operation & Maintenance manuals, Sales Brochures, Service Bulletins, Wiring Schematics, Parts Breakdowns and various other technical documents related to the full line of Hubbell water heaters. Or, if you prefer, please call us at 800-647-3165 and ask to speak to a Sales Engineer.

Where can I purchase replacement parts?

Parts are available for your Hubbell water heater direct from the factory. Please call 800-647-3165 and ask for our parts department. Please have your model and serial number handy.


For Further Assistance Please Contact a Hubbell Tech Support Rep.

Sam Wellington
samw@hubbellheaters.com
203-378-2659 x136
D.J. Dineson
djdineson@hubbellheaters.com
203-378-2659 x125
Hubbell Heaters
45 Seymour Street
P.O. Box 288
Stratford, CT 06615-0288
Tel: 203-378-2659
Fax: 203-378-3593
Product Center
Hubbell Binder

View our current digital materials available in our resource center.

To Product Center  Bullet Point