Electric Low Capacity

Model E

Electric cement lined water heater Model E
  • Light Duty
  • 6 - 120 Gallon Capacity
  • Up to 12KW - 1 Phase or 3 Phase

Model HE / HSE

Electric horizontal ceiling hung water heater Model HE/HSE
  • Horizontal, Ceiling Hung
  • 20 or 30 Gallon Capacity
  • Up to 20 KW - 1 or 3 Phase

Model PBX

Hybrid electric heat pump water heater Model PBX
  • Heat Pump Water Heater
  • 40 - 120 Gallon Capacity
  • 1 or 3 Phase

Model CE 110

Point-of-use electric water heater Model CE110
  • Point-of-Use
  • 1 Gallon Capacity
  • 1000 or 450 Watts - 1 Phase

Model Tankless

Electric tankless point-of-use water heater Model R
  • Whole House / Point-of-Use
  • Availabe 3 thru 27 KW - 1 Phase

Model J

Electric booster water heater Model J
  • Booster Heater
  • Provides 180°F water
  • Up to 88 KW - 1 or 3 Phase

Model JTX

Electric tankless booster heater Model JTX
  • Tankless Booster Heater
  • Provides 180°F water
  • 11 to 54 KW - 1 or 3 Phase

Model SE

Commercial heavy duty electric storage water heater Model SE
  • Light Duty
  • 6-120 Gallon Capacity
  • Up to 58 KW - 3 Phase

Model HX / TX

Electric tankless water heater Model TX
  • Tankless Commercial
  • Highly efficient tankless
  • Up to 54 KW - 1 or 3 Phase

Model SH & H

Large capacity electric storage tank water heater Model SH
  • Large Capacity
  • 80-5000 Gallon Capacity
  • All KW ratings - 1 or 3 Phase
     

Model GX

Gas tankless water heater Model GX
  • Commercial Gas Tankless
  • Integrated Pump
  • 200,000 and 250,000 BTUs

Model GXT

Condensing gas storage tank water heater Model GXT
  • Integrated Tank with Tankless
  • Hydrastone Cement
  • 200,000 to 250,000 BTUs

Model DGX

DI/RO gas fired tankless water heater Model DGX
  • DI/RO Water Heater
  • Gas Tankless
  • 199,950 and 250,000 BTU

Model JBX

Condensing gas tankless booster water heater Model JBX
  • Gas Tankless Booster
  • For Commercial Kitchens
  • 150,000 / 200,000 / 250,000 BTU

Model GSE

Condensing gas storage tank water heater Model GXT
  • Gas Storage Tank
  • Hydrastone Cement
  • 200,000 to 250,000 BTUs
   

Model ST

Steam fired water heater large capacity Model ST
  • Storage Type
  • 80-5000 Gallon Capacity
  • ASME Stamped

Model STX

Semi-Instantaneous Steam Fired Water Heater Model STX
  • Semi-Instantaneous
  • Space saving design
  • Provides 10,500 GPH

Model PS

Storage tank steam fired water heater Model PS
  • Light Duty
  • 80-120 Gallon Capacity
  • For low demand/recovery

Model F

Instantaneous steam fired water heater Model F
  • Instantaneous
  • 7 Sq. Ft. of floorspace
  • Up to 120 GPM
     

Model BWX

Indirect fired semi-instantaneous water heater Hubbell Model BWX
  • Semi-Instantaneous
  • Vertical or Horizontal
  • ASME Stamped

Model BW

Indirect fired storage tank water heater Hubbell Model BW
  • Storage Type
  • Vertical or Horizontal
  • 80-5000 Gallon Capacity

Model Transflow

Indirect fired storage tank water heater model T Transflow
  • Indirect Fired
  • 30-120 Gallon Capacity
  • Utilizes boiler water

Model SLN

Solar water heater Model SLN
  • Solar Heater
  • Vertical Storage Type
  • 30-120 Gallon Capacity
       

Model CR

Electric circulation heater Hubbell Model CR
  • Circulation (Instantaneous)
  • Heavy Duty Construction
  • 25-1600 KW - 1 or 3 Phase

Model ER

Electric hazardous location water heater Model ER
  • Hazardous Location
  • 10-120 Gallon Capacity
  • Up to 58 KW - 1 or 3 Phase

Model V

Electric process industrial water heater Model V
  • Process Systems & Industrial
  • ASME Stamped
  • Up to 88 KW - 1 or 3 Phase

Model ETX

Electric tankless safety shower water heater Model ETX
  • Tankless Emergency Tepid Water
  • NEMA 4 Standard
  • Up to 88 KW - 1 or 3 Phase

Model HD

DI/RO electric hot water heater Model HD
  • RO/DI Water Heater
  • Point-of-Use Heater
  • Up to 88 KW - 1 or 3 Phase

Model D

DI/RO electric hot water heater Model D
  • RO/DI Water Heater
  • 1-120 Gallon Capacity
  • Up to 88 KW - 1 or 3 Phase

Model EMV

Electric safety shower water heater Model EMV
  • Emergency Tepid Water
  • Fully packaged system
  • Integrated mixing valve

Packaged Skid

Model Packaged Skid
  • Customized to your specifications
  • Full featured system ready for your application

Model ME

Electric water heater for shipboard marine use single phase power Model ME
  • Light Duty
  • 6-120 Gallon Capacity
  • Up to 6 KW - 1 Phase

Model MSH

Electric water heater for shipboard marine use large capacity Model MSH
  • Large Capacity
  • 80-5000 Gallon Capacity
  • All KW ratings - 1 or 3 Phase

Model MSE

Electric water heater for shipboard marine use three phase power Model MSE
  • Vertical
  • 6-120 Gallon Capacity
  • 1 or 3 Phase - Up to 58 KW

Model MTX

Electric tankless water heater for shipboard marine use model MTX
  • Tankless Marine Heater
  • Provides 180°F water
  • 11 to 54 KW - 1 or 3 Phase

Model 177

Naval shipboard marine electric water heater Hubbell Model 177
  • MIL Spec Navy Heaters
  • Comforms to MIL-H-965
  • Shock and EMI protection

Integrated Skid

Turn-key hot water system
  • Customized to your specifications
  • Full featured system ready for your application
   

Heating Elements

Electric immersion tubular style heaters
  • Immersion Electric Heaters
  • Flanged or Screw Plugs Types
  • All KW ratings - 1 or 3 Phase

Heat Transfer Coils

Heat exchanger and heating coil water heaters
  • Immersion Heat Transfer Coils
  • U tube type
  • Range of Materials
   
       
Electric High Capacity
Gas Fired
Steam Fired
Indirect
Special Purpose
Marine
Elements & Exchangers
Resource Center
Large capacity electric storage tank water heater Model SH
Still have questions? Complete this form
*Name:
*Email:
*State /
Province:
*Comment:

Model SH & H

ASME Packaged Electric Water Heater

15-1600 KW - All Voltages & Phases
80-5000 Gallon Capacity

The Model SH and H is a fully packaged water heater designed to be a reliable and long lasting source for hot water. Each component is carefully selected to ensure performance in even the most demanding application. Whether you are heating potable water in a commercial building or heating process water in an industrial application you can selet a Hubbell Modell SH or H to do the job. When you specify and install a Hubbell SH or H model water heater you will have confidence in knowing that the owner will be provided with a quality product that is a long lasting and trouble free source for hot water.

Learn More About Hydrastone Cement Lining

cULUS Listed ASME
  • Reliable

    • Only high grade materials used in construction to ensure long operating life
    • Hydrastone cement lining provides superior protection and tank longevity
    • Heavy duty construction withstands demanding commercial/industrial use
  • Packaged System

    • Fully packaged water heater saves time and money during installation
    • All electrical operating controls are factory selected and wired to ensure reliable operation
  • Versatile

    • Full range of styles, sizes, and optional features to meet your exact water heating needs
    • Highly efficient design lowers peak power demand and reduces operating costs

Model SH and H Standard Equipment

Vessel Construction

  • All welded carbon steel vessel designed and built in strict accordance with the ASME Code Section IV and stamped, certified and registered with the National Board of Boiler and Pressure Vessel Inspectors
  • All internal tank surfaces are lined with a minimum of 5/8" thick Hydrastone cement for superior protection and tank longevity
  • Designed for 125 psi working pressure and hydrostatically tested at 188 psi (1 1/2 times the WP)

General

  • Heavy duty 2" thick fiberglass blanket insulation covers 100% of the pressure vessel for maximum operating and minimal standby heat loss
  • Entire vessel is supported on heavy duty integrally welded steel supports for sturdy floor mounting
  • Full five (5) year Non Pro-Rated tank warranty and one (1) year electrical component warranty
  • Bronze ASME rated combination temperature and pressure safety relief valve set at the vessel working pressure and 210°F

Electrical Operating Controls

  • All electrical operating controls are factory sized, selected, wired, tested and mounted in a NEMA 1 enclosure to ensure safe and reliable operation
  • A power distribution block is supplied for single point electrical connection
  • Power fuses rated at a maximum of 60 Amps protect each heating element branch circuit per NEC and UL requirements. Each branch circuit has a maximum rating of 48 Amps
  • Heavy duty definite purpose magnetic contactor with integrally mounted power fuse block assembly switches power on/off to each branch circuit
  • Heavy duty removable flange type copper sheathed immersion heating element provides long service life
  • Fully adjustable thermostat maintains accurate water temperature and is sized by the factory to control the appropriate number of heating element circuits
  • A generously sized transformer provides fused 120V to the control circuit
  • A fully adjustable (100-240°F) safety hi-limit device with manual reset interrupts power to the control circuit in the event of over-temperature water in the storage tank
  • Safety door interlock mechanism interrupts power to the control circuit upon opening the electrical control panel
  • Louvers in the control panel as needed to allow for cooling of the electrical components to ensure maximum electrical component longevity

Outline Dimensions

Model SH (Vertical)

Outline Dimensions

Model H (Horizontal)

Outline Dimensions

Overall Dimensions, Model SH and H

Actual Storage Capacity (Gallons) Overall Dimensions (Inches) Storage Tank Nominal Storage Capacity (Gallons) Inlet Outlet Sizing (NPT) Approx. Shipping Weight (Lbs.)
Vertical Horizontal
Diameter "A" Height "B" Length "C" Width "D" Height "E" Diameter x Length
80* 26 65 60 26 32 22 x 54 90 1 1/2 700
120* 28 75 71 28 34 24 x 63 140 1 1/2 900
150* 30 79 75 30 36 26 x 68 170 1 1/2 1100
175 34 73 67 34 40 30 x 63 195 1 1/2 1500
200 34 82 76 34 40 30 x 72 220 1 1/2 1700
225 34 89 83 34 40 30 x 79 245 1 1/2 1750
250 40 74 68 40 46 36 x 64 285 1 1/2 1850
275 40 80 74 40 46 36 x 70 310 1 1/2 2000
300 40 88 82 40 46 36 x 78 345 1 1/2 2180
325 40 92 86 40 46 36 x 82 360 1 1/2 2300
350 40 94 88 40 46 36 x 84 370 1 1/2 2500
375 46 81 75 46 52 42 x 71 425 1 1/2 2600
400 46 85 79 46 52 42 x 75 450 1 1/2 2700
425 46 88 82 46 52 42 x 78 470 1 1/2 2900
450 46 93 87 46 52 42 x 83 500 1 1/2 3000
475 52 79 73 52 58 48 x 69 540 2 3100
500 52 82 76 52 58 48 x 72 565 2 3225
525 52 85 79 52 58 48 x 75 590 2 3350
550 52 89 83 52 58 48 x 79 620 2 3400
575 52 93 87 52 58 48 x 83 650 2 3500
600 52 95 89 52 58 48 x 85 665 2 3650
700 52 107 101 52 58 48 x 97 755 2 4000
800 52 119 113 52 58 48 x 109 850 2 4300
900 52 132 126 52 58 48 x 122 940 2 4800
1000 52 145 139 52 58 48 x 135 1060 2 5200
1250 58 149 143 58 64 54 x 139 1380 2 5600
1500 58 174 168 58 64 54 x 164 1625 2 6000
1750 64 168 162 64 70 60 x 158 1935 3 7400
2000 64 185 179 64 70 60 x 175 2145 3 8100
2500 76 169 163 76 82 72 x 159 2800 3 8200
3000 76 197 191 76 82 72 x 187 3300 3 8300
3500 88 174 168 88 94 84 x 164 3935 6 FLG. 8900
4000 88 195 189 88 94 84 x 185 4440 6 FLG. 9800
4500 N/A N/A 178 94 100 96 x 160 5015 6 FLG. 10700
5000 N/A N/A 200 94 100 96 x 175 5485 6 FLG. 11600
Note: All dimensions are approximate and subject change. Please reference the submittal drawing for actual dimensions. The tank selections above are shown for convenience. A full selection of storage capacties are available.
* 80, 120 and 150 gallon tanks do not come equipped with a manway.

Formulas To Solve For

((KW x 1000) ÷ Volts) ÷ 1.73 = Amps 3 Φ
(KW x 1000) ÷ Volts = Amps 1 Φ
KW Requirement:
_________ GPH x _________ °F ΔT x 0.00244 = ________ KW
Temperature Rise:
_________ KW x 410 ÷ _________ GPH = _________ °F ΔT
Flow Rate:
_________ KW x 410 ÷ _________ °F ΔT = ________ GPH

Recovery Ratings and Amperage at Selected KW

KW
INPUT
BTU/HR
RATING
Gallons Per Hour (GPH) Heated At Various Temperature Rises Amperage Rating At Various Voltages
60°F Δ 80°F Δ 100°F Δ 120°F Δ 140°F Δ 208V 3Φ 240V 3Φ 380V 3Φ 415V 3Φ 480V 3Φ
15 51,195 103 77 62 51 44 42 36 23 21 18
20 68,260 137 103 82 68 59 56 48 30 28 24
25 85,325 171 128 103 85 73 69 60 38 35 30
30 102,390 205 154 123 103 88 83 72 46 42 36
35 119,455 239 179 144 120 103 97 84 53 49 42
40 136,520 273 205 164 137 117 111 96 61 56 48
45 153,585 308 231 185 154 132 125 108 68 63 54
50170,650342256205171146139120767060
55187,715376282226188161153132847766
60204,780410308246205176167145918472
65221,845444333267222190181157999178
70238,9104783592872392051951691069784
75255,97551338430825622020818111410490
80273,04054741032827323422219312211196
85290,105581436349290249236205129118102
90307,170615461369308264250217137125108
95324,235649487390325278264229145132114
100341,300683513410342293278241152139120
110375,430752564451376322306265167153132
120409,560820615492410351333289183167145
125426,625854641513427366347301190174151
150511,9501025769615513439417361228209181
175597,2751196897718598513486421266244211
200682,60013671025820683586556482304279241
225767,92515381153923769659625542342313271
250853,250170812811025854732695602380348301
275938,575187914091128940805764662418383331
3001,023,9002050153812301025879834723456418361
3251,109,2252221166613331110952903783494453391
3501,194,55023921794143511961025973843532487421
3751,279,875256319221538128110981042903570522452
4001,365,200273320501640136711711112963608557482
4501,535,8503075230618451538131812511084685627542
5001,706,5003417256320501708146413901204761696602
10003,412,0006833512541003417292927792408152113931204
12004,094,4008200615049204100351433352890182516711445
14004,776,8009567717557404783410038913372213019501686
16005,459,20010933820065605467468644463854243422291927
Notes:
1. The KW selections above are shown for convenience. A full selection of KW ratings from 15 to 1600 KW is available by entering the desired KW into the model number.
2. For alternative voltages, including 220, 277, 440, 460, 575 and 600 volt, please contact us directly for full KW selection.

SH and H Model Optional Equipment

Vessel

  • Alternate protective lining:
    Phenolic epoxy resin, Flame spray copper, Hot dip galvanizing, other
  • Alternate vessel construction:
    Stainless Steel Type 304 or 316L, 90/10 Copper-Nickel, other
  • Alternate working pressure:
    To Spec
  • Tank designed, constructed and stamped to section VIII or Section I of the ASME Code

General

  • Skid mounting on heavy duty all welded I Beam
  • Type 304 stainless steel protective jacket
  • Field removable (knocked-down) outer jacket
  • Alternate insulation system
  • Dual energy package provides operational flexibility for electric and (steam or boiler water) power
  • Manway 12" x 16" size
  • Inspection opening 3" NPT size

Electrical

  • NEMA 4 weather resistant enclosure for outdoor/wet locations
  • Explosion resistant construction for hazardous locations
  • Built-in circuit breaker (with or without shunt trip) or a built-in non-fused On/Off disconnect switch
  • Alternate element sheath material (specify: incoloy, stainless steel, other)
  • Specialized heating element construction including: special watt density rating, passivation, electropolishing, or any other feature required to meet the needs of your application
  • Factory installed low water cut out device to disengage electrically the heating element(s) in the event of insufficient water in the tank
  • Dial thermometer and pressure gauge factory installed in the tank
  • Intra-tank circulation pump package with On/Off switch to continuously circulate water within the tank and thereby reduce stratification. All bronze circulator pump is properly sized for the storage capacity
  • Status indicating lamp(s)
  • Audible alarm system
  • Digital display electronic temperature controller. With or without RS485 communication port for remote operation of the temperature controller
  • Building Automation System (BAS) package provides remote operating/alarm capability
  • Factory purchased mixing valve to supply high volume tepid water for safety shower systems

Model Number Designation SH and H



Step 1
Model:
SH = Vertical
H = Horizontal
Step 2
Storage Capacity:
80-5000 Gallons
-
-
Step 3
Lower KW:
5 - 1600 KW

Step 4
Vessel Type:
SL = Cement Lined Steel
GL = Phenolic Lined Steel
M = Hot Dip Galvanized Steel
CN = Solid 90/10 Copper-Nickel
SS = Solid Stainless Steel
Type 304 or 316L

Step 5
Voltage/Phase/Hz:
RS = 208-1-60
R = 208-3-60
S = 240-1-60
T = 240-3-60
W = 277-1-60
T3 = 380-3-50/60
T7 = 415-3-50/60
T5 = 440-3-60
T4 = 480-3-60
T6 = 600-3-60

Example:

SH350-0-90SLT4

A vertical 350 gallon storage capacity water heater with a 90 KW heating element. Tank is cement lined. Power required is 480VAC, 3 phase, 60 Hz.

Model SH/H Specific Questions

Which is better for me, a tankless or storage type water heater?

It depends. A tankless water heater is sometimes referred to as a Point-of-Use (POU) or instantaneous water heater. Due to the relative small physical size of a tankless water heater compared to a storage tank water heater, a tankless option can be advantageous from a space saving perspective and can sometimes be installed closer to where you want hot water (hence the term POU). However, tankless heaters are not suited for many applications, so it is critical that before choosing to go tankless you have carefully considered all of the factors that sometimes make the tankless option more complicated and risky compared to a storage type water heater. In particular, you should understand the operational characteristics, maintenance requirements, reparability, and sometimes significant installation requirements of a tankless water heater before making a decision. Tankless units do not store heated water like a storage type water heater; they only heat water as there is demand and therefore must be sized to meet the maximum flow for the application. In some cases a tankless water heater may improve operating efficiency, but possibly at the expense of user comfort. Hubbell tankless water heaters are available in Electric Tankless or Gas Tankless

What third party approvals are available?

The Hubbell water heater is built to both US and Canadian Standards under UL1453 (water heating only) file KSBZ.E239672 or UL834 (boilers and water heating) file BDJS.E51660. In addition, the Hubbell pressure vessel storage tank is built and stamped to ASME and National Board Registered. Other approvals are available upon request at the time of quoting, including CRN (Canadian Registration Number), NR-13 (Brazilian Regulation Standard Boilers and Pressure Vessels), ABS (American Bureau of Shipping), SASO (Saudi Arabia Standards Organization) and others. Please consult with your Hubbell Sales Engineer to discuss your third party approval requirements.

What is the delivery time?

In most cases the delivery time for a Hubbell water heater is approximately 10 weeks after release for production, but can be 16 weeks or more depending upon the particular requirements of your application. However, there are various sizes and configurations which Hubbell has in stock for “Quick Ship” (as early as next day t to 2 weeks) to accommodate situations that require shorter delivery. Please consult with your Hubbell Sales Engineer to discuss delivery times for your application.

Are parts available from the factory?

Yes. All replacement parts for the Hubbell water heater are available from the factory. Please call 800-647-3165 and ask for our parts department. Please have your model and serial number handy. Most parts are in stock and orders placed before noon typically ship same day. However, it should be noted that the heating element component is typically not a stock item, with delivery times ranging from 2 to 10 weeks depending upon the design, it is recommended that you consider having a replacement heating element on hand if your application is critical.

Why is Hydrastone Cement a better choice over glass lining?

Cement lining provides guaranteed 100% coverage with a minimum thickness of 0.5” over all internal tank surfaces. In comparison, glass lining is approximately 0.005” thick and includes imperfections, pinholes and variation in coverage thickness resulting in portions of unprotected steel tank exposed to corrosion. In an attempt to compensate, glass lined tanks include a sacrificial anode in an effort to slow down the corrosion of the tank. Cement lined tanks on the other hand do not require an anode due to the integrity of the lining. As such, a cement lined tank will far outlast a glass lined tank. For a more complete explanation of the benefits of the Hubbell cement lining please click on the following link Cement Lining

General Questions

Where can I purchase a Hubbell water heater?

There are numerous ways to purchase a Hubbell water heater depending upon the model you desire and your geographic location. The easiest way is to contact Hubbell directly at 800-647-3165 and ask for the sales department where you will be directed to either our local representative or our order entry department for quick and easy ordering.

Where can I purchase replacement parts?

Parts are available for your Hubbell water heater direct from the factory. Please call 800-647-3165 and ask for our parts department. Please have your model and serial number handy.

I don't see the size or feature I need, what do I do?

Hubbell has more than 35 product families available in over 4,000,000 configurations. There are numerous features, configurations and ratings we provide but for practical reasons are are not listed in the sales brochure. If you have a specific requirement and you do not see it in the brochure, please contact a Hubbell Sales Engineer...chances are we have what you need.

What should I know about Legionella disease?

Legionella is the bacteria responsible for Legionnaire’s Disease, an acute bacterial infection of the lower respiratory tract. This bacterium was first identified in 1977 by the Centers for Disease Control as the cause of an outbreak of pneumonia that caused 34 deaths at a 1976 American Legion Convention in Philadelphia. Pontiac Fever is a less severe, non-pneumonia, flu-like disease that is associated with and likely caused by Legionella bacteria. Legionella is a fairly common water bacterium and has been found to exist widely in many surface water sources including lakes, rivers, streams and ponds. It can also be found in ground water sources and some soils. At the levels found in these naturally occurring sources it typically does not pose a threat to public health. When the bacterium enters a domestic water system it can find an ideal host environment of warm water temperatures (105-115°F), stagnant water areas (isolated storage tanks and dead-end piping legs) and ample food sources (sediment, scale, deposits and biofilm). Under these conditions Legionella can rapidly colonize, forming higher concentrations that can pose the public health threat of Legionnaire’s Disease. There are many methods of controlling colonization of Legionella bacteria. However, a widely accepted and preferred method is to maintain the hot water system storage temperature continually at or above 140°F. Unfortunately, the elevated temperature necessary to minimize the growth of and kill Legionella bacteria has the potential to cause serious thermal shock and scalding injuries. As such, many plumbing engineers will specify that the water heater be set to maintain water temperatures at 140°F or higher to reduce the risk of Legionella, but then specify the appropriate mixing valve to ensure safe delivery of hot water to the fixtures. For a more thorough discussion of Legionella please go to here and the following link to the US Department of Labor OSHA information regarding Legionnaires’ Disease OSHA here

My question is not found in these FAQ’s, where do I look next?

Check out the Hubbell Product Center at Here for a complete listing of all technical documentation available by model. Get easy access to Installation, Operation & Maintenance manuals, Sales Brochures, Service Bulletins, Wiring Schematics, Parts Breakdowns and various other technical documents related to the full line of Hubbell water heaters. Or, if you prefer, please call us at 800-647-3165 and ask to speak to a Sales Engineer.

Downloads

Many of our products literature is available online for download. To open these files, a PDF viewer is required. If you do not have one, Adobe provides Acrobat Reader free of charge for viewing only. Use this link to download Acrobat Reader. You may also choose to download the file to your PC for future reference or printing. On most operating systems, simply right-click on the links below, choose "Save target as..." or "Save link as...", choose a location and it will save the document to your computer for future reference.

Model SH & H Specific Questions

My question is not found in these FAQ’s, where do I look next?

Check out the Hubbell Product Center at Here for a complete listing of all technical documentation available by model. Get easy access to Installation, Operation & Maintenance manuals, Sales Brochures, Service Bulletins, Wiring Schematics, Parts Breakdowns and various other technical documents related to the full line of Hubbell water heaters. Or, if you prefer, please call us at 800-647-3165 and ask to speak to a Sales Engineer.

Where can I purchase replacement parts?

Parts are available for your Hubbell water heater direct from the factory. Please call 800-647-3165 and ask for our parts department. Please have your model and serial number handy.


For Further Assistance Please Contact a Hubbell Tech Support Rep.

Sam Wellington
samw@hubbellheaters.com
203-378-2659 x136
D.J. Dineson
djdineson@hubbellheaters.com
203-378-2659 x125
Hubbell Heaters
45 Seymour Street
P.O. Box 288
Stratford, CT 06615-0288
Tel: 203-378-2659
Fax: 203-378-3593
Product Center
Hubbell Binder

View our current digital materials available in our resource center.

To Product Center  Bullet Point